520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for merion station, pa


Map of Merion Station PA
Chris B.

Chris B.


Job Checkin

Performed Precision Air Conditioning Tune Up on system. Replaced the 201 High Efficiency Air Filter. While testing the electrical components found the Blower Capacitor was testing below Rating. Replaced the Blower Capacitor and tested operation. While measuring Refrigerant Charge found Superheat to be high and Subcooling Levels were low. Added 2lbs of 410-A Refrigerant to system to raise Subcooling to proper levels. Added Leak Dye to the system. Due to the system needing refirgerant Charge and adding the Leak Dye to the system, the homeowner would like us to come back out in the next 30-45 Days to inspect the system for the leak. The office will contact to schedule the leak search. The office will follow up for payment due to the homeowner not being home at the time of service.