James was awesome, explained everything, and was very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Helped me understand the problem then made sure what would fix that issue

  • Overall Experience
  • Quality
  • Price
  • Convenience

He got it done!

He very quickly installed the heating element in my new HVAC unit, was in and out and repaired something that was disconnected in my home from the HVAC repair. So 👍 👍 The only reason I gave 3 stars on the ‘convenience’ question was because they were 2 hours later than the late end of the window, which was frustrating because I have million things to do and my time is valuable too… but it all worked out ok. It was all redeemed when they were done so quickly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Great customer service. Explained everything to a T, very happy with my experience and comfortable to do service again

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome, switching companies for service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super knowledgeable, in-depth and very helpful

I got 3 estimates from 3 companies for new central AC. James definitely made all the difference. I will be picking this company for the work! He was very thorough, knowledgeable and extremely good at his job. I have all the confidence in this company because of his expertise and attitude.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome engineer

We purchased a new home and Jane’s came out to check everything out. He was very thorough and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

James was great. He is professional, honest, and very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for new port richey, fl

troy@hot2coldairconditioning.com

troy@hot2coldairconditioning.com Job Checkin

dye test

dye test

troy@hot2coldairconditioning.com

troy@hot2coldairconditioning.com Job Checkin

System maintenance

System maintenance

troy@hot2coldairconditioning.com

troy@hot2coldairconditioning.com Job Checkin

Estimate for a 1 ton condenser and a 9K mini split head


Corey B.

Corey B. Job Checkin

Perform four drain line cleans drains were completely clogged and treated

Perform four drain line cleans drains were completely clogged and treated

James T.

James T. Job Checkin

Today we visited because the AC unit wasn’t working. We learned the system is from 2022 and wasn’t working because of a faulty service disconnect breaker in the air handler. This breaker is a special order for this unit. James was able to get the unit working by bypassing the disconnect breaker. FOR SAFETY THE BREAKER REQUIRES REPLACING We also found the unit is in need of maintenance and there is not an air filter (20x20x1). The old filter was located it seems it was removed when the resident was trying to figure out what was wrong.

Today we visited because the AC unit wasn’t working. 

We learned the system is from 2022 and wasn’t working because of a faulty service disconnect breaker in the air handler. This breaker is a special order for this unit. 

James was able to get the unit working by bypassing the disconnect breaker.

FOR SAFETY THE BREAKER REQUIRES REPLACING 

We also found the unit is in need of maintenance and there is not an air filter (20x20x1). The old filter was located it seems it was removed when the resident was trying to figure out what was wrong.

Geraldo R.

Geraldo R. Job Checkin

Static pressure was reading .25 with fan on high speed. Reduced fan speed to medium and brought static pressure down to .18

Static pressure was reading .25 with fan on high speed. Reduced fan speed to medium and brought static pressure down to .18

James T.

James T. Job Checkin

This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.

This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.

Warren G.

Warren G. Job Checkin

Found a faulty T-6 pro thermostat not sending 24 VT to the reversing valve. Replaced thermostat, checked pressures, and checked wiring. Unit is fully operational at this time. Walkway light was also addressed.

Found a faulty T-6 pro thermostat not sending 24 VT to the reversing valve. Replaced thermostat, checked pressures, and checked wiring. Unit is fully operational at this time. Walkway light was also addressed.

Corey B.

Corey B. Job Checkin

Replaced TXV. Charged the unit to factory specifications, and managed to get the unit to a 17 DEG (85/68)split across the evaporator coils. Lowered the unit fan speed, and balanced the overall air volume of the unit. The unit temperature dropped from 87 to 84 upon completion. Explained to the homeowner that in order for the unit to preform as designed, the system will need to operate and take time while the temperature reaches desired temperatures. (SEE PHOTOS)

Replaced TXV. Charged the unit to factory specifications, and managed to get the unit to a 17 DEG (85/68)split across the evaporator coils. Lowered the unit fan speed, and balanced the overall air volume of the unit. The unit temperature dropped from 87 to 84 upon completion. Explained to the homeowner that in order for the unit to preform as designed, the system will need to operate and take time while the temperature reaches desired temperatures. (SEE PHOTOS)

Corey B.

Corey B. Job Checkin

Replaced Air Filter. (20x2x5) Maintenance completed on prior visit. Unit is fully operational at this time.

Replaced Air Filter. (20x2x5) Maintenance completed on prior visit. Unit is fully operational at this time.

James T.

James T. Job Checkin

Today we visited to reevaluate the unit and determine the best next step. The system has a failed compressor and is 10 years old. The manufacturer, Maytag, does not have the parts in stock and will need to be ordered. The repairs can be done on Tuesday of next week. Since the system is at the end of its expected useful life and requires an extensive repair it is wise to consider replacing it. The replacement can be done this week on Friday. James is waiting to hear back from Michael to confirm plans.

Today we visited to reevaluate the unit and determine the best next step. 

The system has a failed compressor and is 10 years old. The manufacturer, Maytag, does not have the parts in stock and will need to be ordered. The repairs can be done on Tuesday of next week.

Since the system is at the end of its expected useful life and requires an extensive repair it is wise to consider replacing it. The replacement can be done this week on Friday. 

James is waiting to hear back from Michael to confirm plans.

Corey B.

Corey B. Job Checkin

Upon arrival found Failed compressor, tomorrow at 10 till 12 appointment with james.

Upon arrival found Failed compressor, tomorrow at 10 till 12 appointment with james.

Brennan  G.

Brennan G. Job Checkin

Brennan G Today i visited for the system running but not reaching temp. I found the fan speed set to low . I moved the fan speed back to high. We will follow up tomorrow and see if this makes any change

Brennan G
Today i visited for the system running but not reaching temp.
I found the fan speed set to low . I moved the fan speed back to high. We will follow up tomorrow and see if this makes any change

Corey B.

Corey B. Job Checkin

Recorded filter size

Recorded filter size

Corey B.

Corey B. Job Checkin

Found the unit inoperable due to a faulty indoor TX. The pressures are 108 / 330, with a superheat of 30 and sub coil of 16. System is operating at this time.