Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Added two pounds of refrigerant. Vacuumed down drain line

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Added two pounds of refrigerant. Vacuumed down drain line

James T.

James T. Job Checkin

Today we visited to provide pricing to replace/redesign the air conditioning system. The current system is mismatched and not working efficiently. The power bills are a problem with them sometimes being $400+. James put together the preliminary information for Sarah to choose the equipment she likes and sent it over.

Today we visited to provide pricing to replace/redesign the air conditioning system. 

The current system is mismatched and not working efficiently. The power bills are a problem with them sometimes being $400+. 

James put together the preliminary information for Sarah to choose the equipment she likes and sent it over.

Warren G.

Warren G. Job Checkin

This machine is the least expensive to initially install. It uses a single stage compressor and indoor blower motor. This unit is the most similar technology to the current system.

This machine is the least expensive to initially install. It uses a single stage compressor and indoor blower motor. This unit is the most similar technology to the current system.

Corey B.

Corey B. Job Checkin

Need to return to complete the diagnosis system is a box of ice replace capacitor for the blower fan Returned today 10/5/2022 ice has thawed out and checked system operations system up and running cooling at this time

Need to return to complete the diagnosis system is a box of ice replace capacitor for the blower fan 
Returned today 10/5/2022 ice has thawed out and checked system operations system up and running cooling at this time

James T.

James T. Job Checkin

This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.

This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.

James T.

James T. Job Checkin

Today we visited to determine why the AC is not working. We learned the inside fan isn’t working because the control board has failed. After evaluating the entire machine and discovered more work is needed Mike decided to replace the unit entirely instead of spending any money on the 22 year old unit. We will be returning to install a new system.

Today we visited to determine why the AC is not working. We learned the inside fan isn’t working because the control board has failed.

After evaluating the entire machine and discovered more work is needed Mike decided to replace the unit entirely instead of spending any money on the 22 year old unit. 

We will be returning to install a new system.

Tony L.

Tony L. Job Checkin

Completed, Replaced bad condenser fan motor, system checked good and draining properly.

Completed,
Replaced bad condenser fan motor, system checked good and draining properly.

Geraldo R.

Geraldo R. Job Checkin

At the moment everything is functioning normal. Amp draws are fine. Capacitor checks good. Refrigerant levels are good. Filter is clean.

At the moment everything is functioning normal. Amp draws are fine. Capacitor checks good. Refrigerant levels are good. Filter is clean.

Corey B.

Corey B. Job Checkin

1 Time Maintenance performed santi duct blower ok drain line flushed comp ok fan ok cap ok charge ok system up and running

1 Time Maintenance performed santi duct blower ok drain line flushed comp ok fan ok cap ok charge ok system up and running

Tony L.

Tony L. Job Checkin

Repair Option Completed, Replaced bad 70 uf capacitor,temperatures and pressures checked good and draining properly.


Steven A.

Steven A. Job Checkin

Found float switch in condensate pump tripped because condensate pump does not have outlet to plug in. Advised client to call electrician to install new outlet.


Luis@hot2coldairconditioning.com

Luis@hot2coldairconditioning.com Job Checkin

Preventive maintenance on treatments entails. All evaporator coils received self rinse wash. All electrical components and motor and no capacitor Checked for proper operation condition. Recommended to the customer to replace air filter more often.

Preventive maintenance on treatments entails. All   evaporator coils received self rinse wash. All electrical components and motor and no capacitor Checked for proper  operation condition.  Recommended to the customer to replace air filter more often.

David B.

David B. Job Checkin

Club Membership Plus Completed. Inspected system found ac not cooling checked pressures found compressor not running. Checked 70+5 capacitor found it reading 10.26 on the compressor side of capacitor. Also found condenser coil impacted and drain line impacted. Recommend replacing bad capacitor and full preventive maintenance on system. Replaced bad capacitor with new 70+5 capacitor. Completed full preventive maintenance on system.

Club Membership Plus
Completed.
Inspected system found ac not cooling checked pressures found compressor not running. Checked 70+5 capacitor found it reading 10.26 on the compressor side of capacitor. Also found condenser coil impacted and drain line impacted. Recommend replacing bad capacitor and full preventive maintenance on system. Replaced bad capacitor with new 70+5 capacitor. Completed full preventive maintenance on system.

James T.

James T. Job Checkin

Today we found the unit not working because the high pressure sensor was tripped. Once the sensor was reset and the unit turned on we learned the outdoor fan was not running. The fan was over heating and the dual capacitor was bad. With the new capacitor the unit would run, but the fan is over amping and may become a problem soon.

Today we found the unit not working because the high pressure sensor was tripped. Once the sensor was reset and the unit turned on we learned the outdoor fan was not running. The fan was over heating and the dual capacitor was bad. With the new capacitor the unit would run, but the fan is over amping and may become a problem soon.