725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for lewis center, oh


Map of Lewis Center OH
Brandon P.

Brandon P.


Job Checkin

2020 Tempstar AC running in great condition. 20x25x4 air filter in good condition. Check again in 1-2 months, especially with remodeling work being done in the house. Visual inspection of indoor. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 19F with supply temp of 52F. Refrigerant pressures are within spec. Dual run capacitor is within spec. System is operating properly, and efficiently.