Graham M.

Graham M. Job Checkin

Upon arrival discovered unit was not fully reassembled, capacitor was not put back in mounting bracket. Inspected heat exchanger from bottom side, discovered two corrosion points on the secondary. Inspected heat exchanger with camera through limit access. Heat exchanger is getting stress marks on steel but no visible cracks or holes. Performed combustion analysis on furnace during operation and no concerns were found, combustion report photo uploaded. Blower motor capacitor 5mfd tested at 3.06. Blower motor has very minor resistance to it, when spun by hand it stays spinning for about 15-20 seconds, motor doesn’t seem to be in concerning conditions to my knowledge. Replaced 5mfd capacitor with turbo 200 mini and set to 5mfd. Inducer motor has slight vibration to it but it is not a concerning amount.


Jeramie T.

Jeramie T. Job Checkin

FURNACE NOT OPERATING UPON ARRIVAL. Client would like a Furnace inspection due to cost and age of FURNACE. REMOVED HIGH LIMIT TO INSPECT HEAT EXCHANGER. Discovered heavy rust deposits and flaking on all 3 cells inside at first bend. NO signs of holes or cracks at the best of my ability. PERFORMED walk-through with client on Honeywell 800.Client does not have working Carbon monoxide device. INSTALLED 1 FROM TRUCK STOCK. Furnace is not operating at departure.


Jason D.

Jason D. Job Checkin

Install new Bryant HVAC system Equipment: Furnace: 926TC66120V24 AC: GA4SAN46000N Coil: CVPVA6024XMC * Honeywell Vision Pro 8000 * Air Filtration- 1" Standard Filter Rack * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system 10 Year manufacturers parts warranty (Annual maintenance must be performed) 10 Year Compressor Warranty (Annual maintenance must be performed) 20 Year Heat Exchanger Warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)


Jeramie T.

Jeramie T. Job Checkin

Furnace not operating upon arrival. DISCOVERED DEFECTIVE indoor blower motor. Motor receiving 120v and capacitor reading 3uf. Tested with mini turbo 5uf and blower motor not engaging. Client would like to have estimate for repairs and replacement for Furnace. System is not operating at departure


Graham M.

Graham M. Job Checkin

Upon arrival discovered back main unit was not operational. Discovered unit blower motor was extremely hot and producing an awful strong burning smell. Checked capacitor for blower motor and unit was dead 10mfd at 0.0. Replaced capacitor and motor started up with no problem, unit pulling 7.83 amps while blower is operating, unable to see blower amp specs. With motor being under heavy load and overheating like it has, recommending replacement of blower motor for preventative measures. Unit is from 2006 and should be considered for replacement soon if repairs continue to be needed. Two units in the building, both operational at this time but replacement was recommended due to age and part failures on bigger unit.


Nate G.

Nate G. Job Checkin

System low on refrigerant again. Leak sealant was unable to stop the leak due to the size of the hole. Located UV dye all over the evaporator coil. System out of factory 10 year parts warranty. Replace leaking evaporator coil, pressure test with nitrogen, evacuate, and recharge with R410a refrigerant.


Nate G.

Nate G. Job Checkin

Replaced a 15 year old leaking evaporator coil.

Replaced a 15 year old leaking evaporator coil.

Nate G.

Nate G. Job Checkin

AC low on refrigerant again. Previous visit we added refrigerant and leak sealant with UV dye. The sealant was unable to seal the leak due to the size of hole. Tested the heat exchanger with combustion analyzer. It passed. Acceptable to repair/replace AC only.


Nate G.

Nate G. Job Checkin

Diagnosed leaking evaporator coil on a 15 year old carrier AC system.

Diagnosed leaking evaporator coil on a 15 year old carrier AC system.

Nate G.

Nate G. Job Checkin

Diagnostic on a Carrier AC system.

Diagnostic on a Carrier AC system.