Job Checkin

we removed all devices on kitchen counter top and re-deviced the kitchen counter top <br> We spliced all the appropriate wires together then pig tailed off the splice to give the circuits the best and safest possible connection throughout the circuit. Then we installed gfcis on kitchen counter top and line sided everything. We also replaced the garbage disposal switch <br> <br> We removed all the devices outside and replaced them with weather resistant gfcis and in use bubble covers<br> On the side of the home they had a romex wire going outside into a the bottom of a weather proof box with a seal tight whip from a radon fan going into the box with a pvc connector holding it in place in the box<br> We removed the box and relocated it so no romex wire was exposed coming into the back of a new weather proof box and connector. Then I installed a seal tight 1/2 inch connector to properly seal the box properly then we spliced the wires and put on a weather proof blank plate <br> Customer