403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for brooklyn park, md


Map of Brooklyn Park MD
Alex W.

Alex W.


Job Checkin

Removed all receptacles in basement living room area and replaced them There was a total of 3 circuits between the outlets. So I installed GFCIs for two of the outlets and a arc fault gfci breaker for the other two. There was no grounds in the boxes Re wired and redeviced two 3 way switches for the stairs upstairs Replaced a receptacle in daughters bedroom Took a loose wire in sons attic crawl space and put it in a box and blanked it off The dinning room chandelier was hardwired into a receptacle in the daughters bedroom without a switch So I removed the wire because it was a 12 wire attached to a 14 wire. Then ran out of the receptacle box up to a new switch box I installed then I ran a switch leg to the chandelier. I installed a caseta smart switch to avoid any holes being cut in the wall downstairs. The one switch is in the daughters room the remote switch is in the dinning room on a 3 gang switch plate I also removed the support for the chandelier and installed a side mou