Removed all receptacles in basement living room area and replaced them There was a total of 3 circuits between the outlets. So I installed GFCIs for two of the outlets and a arc fault gfci breaker for the other two. There was no grounds in the boxes Re wired and redeviced two 3 way switches for the stairs upstairs Replaced a receptacle in daughters bedroom Took a loose wire in sons attic crawl space and put it in a box and blanked it off The dinning room chandelier was hardwired into a receptacle in the daughters bedroom without a switch So I removed the wire because it was a 12 wire attached to a 14 wire. Then ran out of the receptacle box up to a new switch box I installed then I ran a switch leg to the chandelier. I installed a caseta smart switch to avoid any holes being cut in the wall downstairs. The one switch is in the daughters room the remote switch is in the dinning room on a 3 gang switch plate I also removed the support for the chandelier and installed a side mou