I removed a junction box that was screwed to the floor under the dishwasher in the kitchen. The feed was coming through the floor So I ran a new multi feed circuit from the main electrical panel through the utility room up into the kitchen under the sink then pvc piped it for better protection into a 1900 box. I then re fed the garbage disposal switch which only had a 14-2 wire to it. I replaced it with a 14-3. I installed a QO arc fault 2 pole 15 amp breaker And I installed 2 gfcis under the sink. I then put a company supplied cord on the garbage disposal and a customer supplied cord to the dishwasher. I tested the garbage disposal but not the washing machine as it wasn’t hooked up to the water line yet Customer has a 18 month warranty Labeled circuits on panel