Alex W.

Alex W.


Job Checkin

Customer originally called because a lamp post was out after inspecting the lamp post being out I found it was on a GFCI breaker and as a safety feature if water gets into the components of the lamp post the GFCI breaker will automatically trip to prevent harm to anyone who touches the lamp also customer called for multiple small projects around the house. Customer removed A wall in the basement and had two receptacles hanging by the wires so I cut the wires and installed a two gang new work junction box in the joists to the expose ceiling then I ran a wire from the junction box over to the other end of the basement where customer wanted to install two new tamper resistant receptacles. Then I removed a blank plate To a junction box near the electrical panel which fed the lamp post out front the customer wanted a receptacle there so I pigtailed off the existing splice and installed a tamper resistant receptacle. I also ran a dedicated circuit from the main electrical panel in the basem