403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for fulton, md


Map of Fulton MD
Michael W.

Michael W.


Job Checkin

This estimate includes the installation of a 240V 20A dedicated circuit for the new mini split AC system on side of home. We shall terminate circuit into a disconnect. In addition we shall diagnose the and make safe the abandoned baseboard heater wiring. We shall also install a whole home surge protector and correct the double tapped neutral wires in the panel. Lastly we shall install arc fault protection for the aluminum 120V circuits in the home. We have installed the new circuit and disconnect for the mini-split AC unit on the side of home. We shall return next Friday to complete the remaining work. We have returned and installed the arc-fault breakers, surge protector and we have deleted the abandoned wires in panel associated with the baseboard heaters. We have also tested wiring at baseboard heater locations and ensured they are not live.