403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for gambrills, md


Map of Gambrills MD
Michael W.

Michael W.


Job Checkin

Original call was to check power to exterior and garage. After checking the circuit, all wiring came from the gfci in the panel room in the basement. This circuit powers the exterior receptacles, utility room and panel room room lighting as well as garage lighting and garage door receptacles. Several receptacles were without a neutral and lighting was without power. After dissecting the circuit I found all terminations were made with the stab in method. I recommended that these devices be replaced and remove the lighting from the load side of the GfCI protection. We installed new gfci receptacles on the rear exterior of home and the basement HVAC closet. In addition we corrected all terminations along circuit.