Reason for today’s visit was to assess the power loss issue in the second-floor middle bedroom as well as the master bathroom lights. Final inspection customer show me panels and the breaker that controls the rooms where the power loss was located and we noticed the third breaker from the top left was in a tripped position. Reset breaker and a restored power loss to the rooms. While inspecting the panels I noticed a buzzing noise coming from all three of the arc fault breakers located in the left panel. This is an early indicator of the breakers failing. I pushed on the breakers to make sure they were engaged fully and they were. We recommend having the three generation one arc fault breakers (BR series) replaced. We also found that neither panel had a whole home surge protection.