Customer will buy a car charger and when he does he will call office to schedule a appointment for us to return to run a 50 amp circuit from main electrical panel in garage to the back of the garage through the wall in a bulk head. We will install a 2 pole 50 amp br breaker. We will also fix a double tapped 15 amp electrical breaker. This comes with a 1 year warranty We ran a 6-2 seu cable from the main electrical panel to the customers desired location for the car charger We ran a piece of pvc up the wall to protect the wire into the customer supplied car charger that i mounted. Then i installed wires and terminated the wires at the car charger I then ran the wire into the main electrical panel and installed a 2 pole 60 amp br breaker. We ordered a 2 pole 50 amp br breaker but will not be in until beginning of march due to national shortage in certain brands in material. We will contact customer once we have the breaker and we will install the 2 pole 50 amp breaker Customer has a