Pride Plumbing was called out for a slow flushing Sterling toilet, two showers that needed repairs, and a water heater not heating the water properly. First, we inspected the slow-flushing toilet and determined that the cause of the slow flush was the actual ceramic toilet itself and not the components inside the toilet tank. Next, we inspected the shower in the guest bathroom and found that it needed a new trim kit and shower head - its three-handle shower valve was fine. Then, our inspection of the master bathroom shower found that it needed a new shower head, trim kit, and three-handle shower valve. Finally, we inspected the water heater and found that its thermostats were set to 112 degrees. We provided a cost estimate to replace the toilet, make the needed repairs in the showers, and set the water heater's thermostats to the manufacturer recommended 125 degrees.