Found Walk-In Freezer unit a little low on refrigerant due to a leak caused by a loose flare nut on the inlet of the receiver. I tightened the nut and the leak stopped. I added refrigerant and the temp is dropping. I noticed the defrost timer motor was noisy and the dial was a stiff to turn, so I replaced it as well. Box is at 0 degrees and dropping.