1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for port matilda, pa


Map of Port Matilda PA
Service C.

Service C.


Job Checkin

Found CLE Steamer unit on but not steaming. Removed side panel and found sight-glass float not filled and water running down drain. Removed drain valve solenoid and installed one from van. Valve still not closing. Tore apart drain valve and found rust build up stopping valve. Worked valve till sliding more free. Tested and now closing. Let fill and began heating and steaming. Also found issue with timer. When gets down to 5 minutes starts sending erratic voltage to condensate valve opening and closing very fast. Recommend replacing drain valve and timer. Customer will need quote sent to okay repair. 106524 drain valve - 20476 timer