checked Cleveland steamer unit, would run for awhile then shut off - pulled side panel bowls are starving for water. tested water pressure from out side of everpure filter system to supply line. has good pressure into filter but very little out. looked on truck for filter ,didn't have in stock. there's no by pass on system. also found filtered water going to condensate. they have their own plumbers but he's in a meeting. explained to chef stewart they need to move inside water line to supply water and change filter. they have ecolab filters they use. let stewart know the reason steamer is not working and that manufacturer won't cover today. unit is down require attention on their end. unit is operational after water pressure problem is fixed.