824 S Central Expressway, Suite 100
Anna, TX 75409
903-482-4900

Job Locations
for anna, tx


Map of Anna TX
braydenwebb@hotmail.com

braydenwebb@hotmail.com


Job Checkin

1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Measured high start amps on condenser. This is an indication that the unit is pulling more power than is good for the unit. This could be due to fluctuations in the power grid. Over time this will lead to excessive wear and tear on the unit. I discussed adding a hard start kit to the unit to pr