Arrived on site to perform furnace diagnostic on 1988 comfortmaker heater. Upon arrival Chris stated over the phone that system is creating burning smell while heating the home. He recently bought the house about a year ago and he’s unsure whether or not repairs or any maintenance has been done ever. Performed diagnostic on system and found that unit is in very bad condition. Inspected heat exchanger and found severe corrosion and heatspots marks. Burning smell only starts when heat exchanger is ignited. Found no Burning smell coming from indoor blower cabinet although Cabinet is heavily covered In dirt and debris and filter has not been swapped in a very long time. Overall inspection showed that furnace is severely worn out and heat exchanger is most likely defective. Main concern would be that heat exchanger is possibly cracked in locations that are not visible. Ultimately the 34-year-old furnace is past design life becoming unsafe and unreliable. Advised Chris that there is not mu