Job Locations
for aston, pa

Brian B.

Brian B. Job Checkin

Performed heating maintenance, checked air filter ok. Serviced humidifier, cleaned and replaced water panel, started humidifier. Cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections, measured capacitor values. Started gas furnace, tested limit and safety switches, measured fuel pressures and performed combustion test.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, replaced air filter. Blew out condensate drain. Cleaned condensate pump. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge, found system low on refrigerant charge. Recommend replacing system vs charging up due to age and R22. Found a filter drier installed backwards and all soft solder on all joints.


Brian B.

Brian B. Job Checkin

New Maintenance Plan 2021-2022 Performed cooling maintenance, checked air filter ok. Blew out condensate drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Brian B.

Brian B. Job Checkin

Checked no cooling complaint, set thermostat to cooling, blower runs but no outdoor operation, found contactor pulled in and 240 volts to unit, found a bad contactor. Replaced single pole contactor. Started air conditioner, checked operation ok. Part is under warranty.


Kurt M.

Kurt M. Job Checkin

Found that the customer has been having issues with water coming down through theceiling from the air handler. Found that after looking over System, found that the drain was not pitched away from the air hander ( took photos) . Also would recommend having an eztrap installed on drain it self to shut down the system before water overflows the evaporator coil pan. Drain would need re ran to a different location to get proper pitch away from the air handler. If this could not be achieved, air handler would need to be raised up to create more fall away from the air handler. Also found that insulation inside the air handler was wet from water not draining away from system. One other recommendation I would make is to also check static pressure readings at air handler.


Kurt M.

Kurt M. Job Checkin

Looked over relocation job over a/c system. Unit has been diconected this past fall and the driveway was widened. Homeowner is looking to have the unit moved to other side of garage. Refrigerant lines, low voltage, and high voltage will need re- located. Will go over job with our office and provide homeowner a quote for relocation..


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, checked air filter ok. Cleaned condensate drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, checked air filter ok. Cleaned condensate drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Chris B.

Chris B. Job Checkin

Performed cooling maintenance, replaced standard air. Cleaned condensate trap and drain. Checked voltage, amperage and electrical connections, measured capacitor values. Found outdoor dual run capacitor reading low on the compressor side. Replaced capacitor with supplied capacitor. Started air conditioner, Checked refrigerant charge and temperature drop across coil


Luis T.

Luis T. Job Checkin

Replacement of new exhaust fan motor, new belt, need to removed pulley and all electrical wiring, after installation of new motor check operation. 4-16-21 Luis and Barry Remove existing exhaust motor and pulley installed new motor and existing pulley also putting new belt check exhaust operation OK. Motor is wire 208/230 three phase voltage


Luis T.

Luis T. Job Checkin

Tested and verified voltage before and after switch of pool area exhaust fan. Windings of motor are noticeably burnt One lead from motor is detached. Will provide estimate for new motor and belt.


Luis T.

Luis T. Job Checkin

No heat, customer lost heat sometime during night, found system in idle mode upon arrival, thermostat calling for heat but signal at board, quoted to replace thermostat customer ok with repairs, installed smarty T6 professional series set up programming on stat test furnace performed combustion test ok


Chris B.

Chris B. Job Checkin

Service call that the Gas Boiler was working but was making loud vibrating noises and swooshing sounds from the baseboards. Upon arrival turned thermostat up to turn system on to monitor. After system starting heating the baseboards could be heard making a loud swooshing noise due to air being in the lines. Also found Expansion tank was full of water. Isolated and Purged baseboard loop and drained Expansion Tank. Put system back in operation to test. Allowed system to fully heat up and cycle on/off. Monitored water pressure and temperature. Checked baseboards and all rooms were getting hot with no noises from the baseboards. Would recommend having Boiler serviced each year and would also recommend having the AC serviced before the summer time.


Chris B.

Chris B. Job Checkin

Returned to site to test Oil Boiler after Oil Delivery. System was in operation upon arrival and at Setpoint on thermostat. Turned Thermostat up to test operation. Measured 0.62 Amps on Circulator Pump. Checked Baseboards to ensure they were getting hot. Performed Combustion Test, Smoke Test, and Draft Test on system. Adjusted Air Band on burner due to improve combustion readings. Performed Smoke Test again after Air Adjustments were made. Ran hot water to ensure Aquastat was working with the domestic coil. Combustion Readings within standards upon completion. Cycled system upon completion.


Brian B.

Brian B. Job Checkin

Checked no heat complaint, found no call from thermostat, checked thermostat, found display flashing heat and fan. But no call to W. Jumped out thermostat. Furnace comes on and heats. Found a bad thermostat. Customer is going to replace the thermostat.