520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Local Reviews
for west brandywine township, pa

Rated 4.9 out of 5 stars based on 15 customer reviews

Great Service by Dibiase

Kurt did a great job servicing the HVAC unit. No issues. ALl done very well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Technician was great. Provided a lot of important information to me. Friendly

See above

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very satisfied with this service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Joe Dibiase’s team provided great service again, even though I’m dialing with a faulty manufactured unit. I look forward to the day where they will only have to perform just routine maintenance. Overall however very high grades.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Louis did a great job as usual. Found a bad switch quickly and replaced it without issues.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Kurt and his team did a great job replacing a defective coil that was under warranty in a timely manner and without additional cost.


Response from DiBiase Heating and Cooling Company:

Phil, thank you for review and thank you for trusting us to service your unit!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very quick service, fixed the problem

  • Overall Experience
  • Quality
  • Price
  • Convenience

Havoc maintenance

Great work

  • Overall Experience
  • Quality
  • Price
  • Convenience

System down

Kurt did great. However being charged $160 extra on top of the $84 for the visit is totally unfair. And that is for a spliced wire. No parts or anything else. If that doesn’t get severely reduced, I will be looking for a different vendor. Because the trust will be broken.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

perfect

Arrived on time, could not have been more professional, Excellent service. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

We have received excellent service from DiBiase Heating and Cooling Company. The administrative staff is friendly and professional and the service technicians are prompt, courteous and knowledgeable. I highly recommend this company to anyone seeking HVAC service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Excellent service, kept me informed & very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing service

I called many heating companies to come out and check my unit but DiBiase heating within an hour called me back and got my heat working again. It's only been about an hour since they worked on it but my home is heated again with no problems. Thank you guys again for doing a great job. Definitely 5 star satisfaction rating.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for west brandywine township, pa

Joseph D.

Joseph D. Job Checkin

Arrived to assess no heat issue. Found error code history and active error code to be EE0 (Incomplete ignition). Cycled furnace and found that burners were not tinting at all. Removed burners, cleaned burner face surface and in between crossover ports of rust. Tested operations in high fire and low fire. Burners are now lighting across and trial for ignition successfully completing. Also verified inducer draft usuing manometer and flame rectification circuit. Recommend upgrading burners to stainless steel which are now available from manufacturer. Also left estimate to replace burners with equivalent standard burners (not stainless steel; labor only) For the time being burners/furnace is operating well, but burners will become corroded enough again that this can recur.


Shawn R.

Shawn R. Job Checkin

Arrived to find master bedroom mini split leaking from condensate pump, made sure line was clear and found the line was pinched putting strain on the motor which caused the pump to leak at a seal. Need to return with condensate pump to resolve issue and do maintenance on the systems.


Kurt M.

Kurt M. Job Checkin

Performed precision a/c tune up on amana heat pump system. Replaced 14x30x1 air filter. Checked all electrical conections and components. Blew out condensate drain. Checked temperature split. Checked refrigerant pressures and temperatures at indoor and outdoor units. A/c system is working fine at time of service.


Kurt M.

Kurt M. Job Checkin

Performed precision oil tune up on Weil McLain oil boiler. Replaced nozzle. Replaced garbar model r oil filter. Brushed and cleaned very dirty oil boiler. Found chimney was completely covered in soot. Told homeowner to have chimney professionally cleaned and inspected. Performed smoke and combustion test. Oil boiler is working fine at time of service.


Luis T.

Luis T. Job Checkin

Performed ac tune up check electrical low and high voltage connections ok replaced air filter 401, flushed drain test pump ok, check airflow supply and return air ok blower motor and cap ok, outdoor unit refrigerant pressures contactor ok found capacitor reading below tolerance provided an estimate to replace capacitor and install super boost customer approved repairs, replaced capacitor and add super boost to system cycle ac unit ok, provided an estimate to replace condensation pump and vinyl tubing Replacement of capacitor and super boost Replacement of air filter. Would recommend Start thinking on system replacement due age


Kurt M.

Kurt M. Job Checkin

Found oil furnace locked out at the primary control . Hit reset button and oil furnace tried to fire immediately. Oil pump has an oil valve on top and was opening immediately. Found 120 v going to oil valve even when primary control was locked out on reset. Replaced primary control with electronic universal control. Also replaced junked up .85x60 a nozzle and performed combustion test. Oil furnace is working fine at time of service.


Barry P.

Barry P. Job Checkin

AC Tune Up 2.5 Ton Trane system Measured temperature split. Measured static pressure. Checked all wiring, controls, electric motors and components. Checked drain. Both coils are in good condition. Checked refrigerant pressures and diagnostics. 16x25x1 Filter ok Air conditioner is operating well at the time of this maintenance.


Shawn R.

Shawn R. Job Checkin

Arrived to do 6mo ac maintenance, checked thermostat, checked filter, checked temperature split, checked and tightened all electrical connections, cleaned and primed ez trap, checked compressor amp draw and condenser fan motor amp draw, checked refrigerant pressures. System is working correctly at this time.


Luis T.

Luis T. Job Checkin

Arrived to do a heating maintenance and address a loud vibration sound from the system. Found the sound was cause from the bottom of the unit vibrating from pulling in air. Secured this to keep it from making a sound. Then we went ahead and did the maintenance which we found the igniter had signs of wear on it which was the white patch from where it’s hot spotting, then checked and cleaned the burners which are not aligned correctly and are rusted in between the burners not allowing for full flame carry over on every attempt to light and not always allowing for flame rectification. Checked the rest of the system and ensured all electrical connections and components were tight, checked combustion analysis and temperature split. System is currently working. Also checked the hot water heater and found the expansion was waterlogged and the hot water heater is 15 yrs old, so we recommended replacement of either the expansion tank or the hot water heater Also recommended an igniter and b


Barry P.

Barry P. Job Checkin

Heat tune up for 80KBTU 2-stage propane furnace. Made call for heat from thermostat. Visual inspection of heat exchanger and burners: Good Checked hot surface ignitor resistance and looked for cracks during start up. Cleaned flame sensor. Checked pressure switches and components. Checked all wiring/electric motors and components. Measured static pressure. Measured temperature rise. Combustion draft test:Good Found lead on low pressure switch was lose. Secured connection Found return static pressure of .46” which is high. Also saw error code in CoolCloud “Blower motor operating outside Limits”. Which indicates controls shut system down on a few occasion as a result of high return static. Strongly recommend adding a return to establish design condition. Had conversation with homeowner and he informed us that these error codes occurred during a bathroom remodel during which the remodelers blocked off return. Dining room is probably the best place to add a return. Furnace is o


Barry P.

Barry P. Job Checkin

Found CoreSense module with red “Trip/Lock” led. Two flashes. Checked 45-5uF capacitor reading 32uF between Common and HERM. Replaced 45-5uF capacitor. Changed Honeywell T6 Pro WiFI stat to lock electric heat out above 40F in system setup options. unit Locked out on low pressure. I did charge the system to design conditions but stuck with system making a secon call for heat. Lo side pressure dropped from 96 to 68 at this time. Did an electronic leak search and found leak at liquid line service valve near Schrader. Replaced shraeder core. Tested system. 98F Supply 67FReturn Pressures 95/351. System is operating well at the time of this maintenance.


Brian B.

Brian B. Job Checkin

Found intermittent blower motor limit - will order and come back and install Replaced blower secondary limits. Removed blower assembly. Replaced both limits. Installed blower. Cycled furnace and checked operation ok. Updated cool cloud software.


Brian B.

Brian B. Job Checkin

Checked no cooling complaint, found breaker tripped to outdoor unit. Reset breaker, air conditioner started, checked refrigerant charge and temperature drop ok. Checked voltage, amperage and electrical connections, measured capacitor values ok. Checked main panel, found all connections tight. Found no reason for breaker trip.


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on Bosch Heat Pump system. Reviewed installation and answered all questions homeowner had. Completed checklist form in system. Replaced the 18x30x1 Air Filter. Collected check for the balance of the Installation. Tested Wet Switch and tested Condensation Drain. While install could have been a little cleaner up in the Attic at the Air handler this passed the QA Inspection. Homeowner would like to sign up for the Service Plan at the Six Month Inspection.


David B.

David B. Job Checkin

Reclaimed and removed old airhandler from attic. Broke down into sections to removed from attic. Installed a new Bosch airhandler on existing platform in attic. Put a auxiliary drain pan underneath. Flushed copper lines from indoor unit to the new amana heatpump. Brazed and leak checked with nitro and bubbles. Put heatpump on pump up feet and on a level plastic pad with crush stone underneath. Installed a new disconnect box and electrical wiring to unit. Installed a new condensate drain with an ez trap wired into unit. Put a wet switch in drain pan as a safety. Tested unit in cooling and charged unit as needed. Tested condensate drain and checked for leaks. Modified supply metal as needed and taped and insulated all ductwork. Installed a t6 thermostat. Us timer not home payment not collected. Left house on cooling at 75*it was 87* in the house.m