Today I arrived on site to address the reported issue with the HeatPump condenser. Service Actions: Identified the HeatPump condenser on the left side of the house heating system as the source of the noise complaint. Discovered low pressure within the system. Charged the system with 3 lbs of R410A refrigerant. Verified the system is now operating correctly. Upon arriving at the property, the client was not on the property. The customer left the door unlocked to give us access to verify the system. I proceeded to run the system. I didn't find any noise at the time of the verification of the unit. I noticed that the condenser coil was freezing, which indicated signs of low system pressure. I checked the system pressures, Pressures out of ranges. Contact Bosch tech support to check the operation and temperatures of the system. Tech support confirmed and recommended that I add refrigerant to the system taking into account the length of the system line set. In total I added 3 Lbs
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-0036EA0C02B34BA79471CAEFD2627740 Return to replace high limit on front left side unit: * power is off to the system * shovel out path and work area to package unit * dismantle package unit and fam controls to access the high limit * crawl inside the package unit from the blower door and removed the existing high limit * install and secure new high limit in place and connect low voltage wiring * crawl out of package unit and assemble and secure fan controls back in place * close blower door and return power to the system * call for heating at thermostat- system fires and is on and running normally * monitor operations for over 30 min- normal operations * cycle system on and off- no faults * close up and secure all doors back to package system * repair is made- system tested and operational
Completed demo and Removal of heat exchanger of the front left side field package unit. Removed supply duct from package unit and temporary patched all duct work to return to install new heat exchanger. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-7C6F-AE891F3A6DC540F2AB4536B3CF621061
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-757F748C835A4C77A28ADD89B4556F00 To replace the capacitor for the indoor blower motor Completed heating maintenance on one heat pump system with electric heat checked electrical and mechanical components and electrical connections replaced the capacitor for the indoor blower motor sprayed and checked evaporator coil also checked electric heat checked systems operation and left system working filter 14+14+1 supplied by homeowner
Today I arrived on site: Condenser Fan Motor Replacement: Replaced the condenser fan motor on the sunroom heat pump system. System Verification: Confirmed the heat pump system is now operating properly. Upon arrival at the property. The owner is not on the property. The housing contractor showed me and explained to me what the defective scam was. I proceeded to check the condenser unit. I found in fan motor making noise. I proceeded to disassemble the defective fan motor. I proceeded to clean the work area. I proceeded to disarm the defective fan motor and installed the new fan motor in the unit. I made the connections and adjustments necessary to conclude with the installation of the new condenser fan motor for the HeatPump system of the sunroom. I concluded with the installation of the new fan motor. I started the system and monitored for about 15 minutes. Check the split temperatures inside the sunroom. Return temp:55F Supply temp:100F This system stopped operating correctly at thi
Preform maintenance on (3) carrier ductless heat pumps (2) ducted heat pumps and (4) package carrier RTU: Carrier ductless equipment: - dismantle indoor heads - Chemically sprayed and washed air filter filters, clean and clear - Chemically sprayed, brushed and rinsed, evaporator coils, clean, and clear - Chemically sprayed and polished primary pans, clean and clear - Chemically treated primary pains and added condensate tablets - Perform full condensate pump cleanings on all three indoor heads - Polished and wipe down cabinets and all equipment - Replaced and dated 16 x 20 by one and 14 x 24 by one air filters - Tested remote / thermostats and called for heating- all systems on and running - Check air flow and temperature splits- okay - Check outdoor condensers - Cleaned and checked outdoor electrical wiring- okay - Systems are fully maintained and operational There is only 1- remote to control all three heads and it is broken- recommend new remotes for carrier ductless heat pump
AC System. Today, I arrived on site to perform an A/C system tune-up and cleaning. Here's what I did: Checked the blower motor and thermostat for proper operation-okay. Air filter: replaced. Checked and cleaned the exterior jacket and interior cabinet-okay. Found the blower wheel-okay. Checked the ductwork-okay Washed and cleaned the indoor Evap coil. Checked and cleaned condensate pump and drain line, treating it with anti-algae. Monitored the refrigerant operating pressures-okay. The refrigerant type is 1x) R22. Inspected the safety devices and found them to be operating properly. Inspected the electrical disconnect box for safe installation-okay. Inspected and tightened electrical wiring connections-okay. Tested and inspected the contact, which is not burned Inspected the electrical for exposed wiring-okay Inspected and tested the capacitors-okay. Inspected the fan blade-okay. Cleaned the condenser coil and removed debris. Checked the service valves for proper operation - okay. Mon
AC System Tune-up on a Carrier AHU and a Trane condenser unit. Today, I arrived on site to perform an A/C system tune-up and cleaning. Here's what I did: Checked the blower motor and thermostat for proper operation-okay. Air filter: replaced. 16x22x1 Checked and cleaned the exterior jacket and interior cabinet-okay. Found the blower wheel-okay. Checked the ductwork-okay Washed and cleaned the indoor Evap coil. Checked and cleaned condensate pump and drain line, treating it with anti-algae. Monitored the refrigerant operating pressures-okay. The refrigerant type is 1x) R22. Inspected the safety devices and found them to be operating properly. Inspected the electrical disconnect box for safe installation-okay. Inspected and tightened electrical wiring connections-okay. Tested and inspected the contact, which is not burned Inspected the electrical for exposed wiring-okay Inspected and tested the capacitors- note: The starter cap of the condenser unit was replaced on this visit. Inspected
New Weil McClain gas-fired boiler and indirect hot water storage tank installed after emergency during COVID-19 pandemic.
Trane High Efficiency Heat Pump installation
Hydro heat American Standard Heat tune-up