Gas Steam Boiler Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, vacuumed-ok Check and cleaned flame sensor & Pilot Assembly-ok note: thermocouple was replaced on this visit. Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Flue Pipe-ok Check GVD- Flue Damper-ok Check LWCO-okay Check and cleaned pressuretrol pigtail-ok Check and make leak test-ok, it is not leak at this moment Check relief valve-ok Check and clean pressure retrol-ok Check Automatic water feeder-ok Check Temperatures & settings-ok Flush boiler twice. Check and run Thermostat- operating Check and checked HWH.(11 years old) Check for leak, no leakage at this moment. Check gas control valve-ok Check safeties-ok Check air combustion and draft-ok HWH operating fine at this moment. Run and test system, runs fine, left system operating well at th
Today I arrived on site Aquastat Relay Pump Installation: Installed a new Aquastat relay pump. This pump is for the kitchen area heating system. System Status: Systems operating normally. I returned this time to install a new Aquastat relay pump for the kitchen area. I proceeded to disassemble the defective relay pump. Disconnect the cable from the defective relay. I proceeded to put the Aquastat relay pump in its place. I proceeded to make the connections and adjustments necessary to conclude with the repair. I complete the repair successfully, ran the system And Monitoring for about 15-20 minutes. The system responded correctly. There were no failures or malfunctions during the monitoring. I showed him and gave him the details of the work done. The client thanked and was satisfied with the repairs. The client was left with the DHW and the Heat operating correctly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-AA1C6AD38B1E44D
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-47F7BE2D8C8943E2A901396254464BB3 Return to preform flushing of steam boiler as well as diagnose overheating in home: * at arrival the boiler is OFF- main burner is OFF * found the main steam thermostat set for 60 but reading 75 degrees * found the hot water radiator yo-yo thermostat set for 65 and reading 68 * cycle heating on and off from Both thermostats multiple times- Boiler turns on and off normally each and every try * confirm voltage is correct * Performed draining on steam boiler: Begin to drain water from the steam boiler, but no water is draining from the boiler drain- plugged * Clear blockage in boiler drain * Continue to flush and drain 8+ buckets of water from the system- okay * return power and test system operations- cycle heating on and off for both steam and hot water radiators- Normal operations * Found that none Hot water radiator piping is heating up Even though the circulator pumps
Today I arrived on site Aquastat Issue:Identified an aquastat malfunction in the kitchen zone. Confirmed the aquastat relay required replacement. Confirmed automatic air vet required replacement. Upon arrival at the property. The client explained to me that the tstat of the kitchen area is not working properly. The client mentioned that the tstat is set up to 72 but the temperature does not rise more than 68F. Confirm that the tstat is set up to 72 and registering an ambient temperature of 67-68. I proceeded to verify the system. I found that the Aqua-stat relay in the kitchen area is not working properly. I showed her and explained to the client that the Aquastat needs to be replaced. The client said that she will contact the office to schedule the appointment to replace the defective Aquastat. Office to follow the client to confirm the repair. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-D7E50E77599A4F589D3568B68B7FE672
Performed heating maintenance on one gas fired Hot water boiler removed and clean burners and clean standing pilot assembly replaced thermocouple clean burner tray checked expansion tank and automatic water feed turn system on and checked boiler operation left functional also performed Heating maintenance on four Hydro air handles check blowers, and Blower motors checked heating coils and sprayed replaced filters April air 210 Four filters in total turn systems on and checked operations diagnosed Heating zone Honeywell R845A relay for the living room is malfunctioning for proper operation of the system this relay has to be replaced all other systems are functional Office personnel please follow up with the homeowner for a price quote for a Honeywell relay R845A
Return visit to replace 3 blower capacitors and a flame sensor for the gym main area system. Also the system in the gym main area is not functioning in heat mode. Found the system locked out this was due to the flame sensor being bad. Replace flame sensor and checked all operations. System is fully operational with no further issues. Capacitors were replaced on all three furnace blowers. All units are operating properly repair is completed. https://visionshare.xoi.io/?id=msb88bf22a-575d-i184-106a4b0cb834-uF83-d50310f62e82
Upon arrival spoke with customer. Customer is explaining that main thermostat was reading ambient temperature of 77 while thermostat sat for 64F degrees. Inspected thermostat, check thermostat programming. Program is set for temperature of 70 throughout the day 62 a night. Customer currently have thermostat holding temperatures of 64F degrees. Inspected boiler and had thermostat call for heat. Boiler is on / running when receiving call from main steam thermostat. Boiler shut down when thermostat stopped calling for heat. Cycle boiler on once more for hot water loop. Boiler ran and reached set temperature before shutting down. Boiler is operating normally @ this time. Explained to customer the possibility of thermostat having an intermittent issue. Customer will monitor thermostat temperatures and follow up with us if thermostat needs to be replaced. Boiler is left operational @ this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-0E3D714B194D452F8
I returned to add a steam boiler treatment cleaner. I proceeded to drain the unit multiple times. I added clean water to the system. I proceeded to dilute the chemical to add it to the system. I concluded with the steam boiler cleaner. I showed it to the client and explained to him about the process carried out on this occasion. - Richard assisted the customer with a steam treatment for their boiler, explaining the process and guiding them through the steps. - The customer expressed a desire to learn how to perform the procedure themselves in the future. - Richard provided instructions on how to properly operate the levers and switches involved in the process. - The customer mentioned previous difficulties with the boiler, which Richard addressed by explaining the correct procedure. - Richard planned to add a steam cleaning treatment to the boiler and explained the expected changes in water color during the process. - The customer seemed satisfied with the assistance and the impr
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-82F76790F2AA48B59B6C0568A7D3ECCE Completed heating maintenance on two furnace removed and clean the igniters and the flame sensors also cleaned burner tubes replaced filter filters18+18+1 and16+16+1 also checked blower wheels and electrical components and mechanical components highly recommended to replace the neutralizer rocks for the system. Located in the basement systems are functional at this time. Left thermostat set to 98° as requested by homeowner left systems working
Checked first floor Trane air handler with hot water heating coil for no heat checked circulation pump and coil had to purge air out of the loop tested system operations left system working highly recommend to replace the automatic air vent on the return hot water line View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-B0A0BFA4A4284F63B37EA4A80D48A6DB
Gas Steam Boiler Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, vacuumed-ok Check and cleaned flame sensor & Pilot Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Flue Pipe-ok Check GVD- Flue Damper-ok Check LWCO-okay Check and cleaned pressuretrol pigtail-ok Check and make leak test-ok, it is not leak at this moment Check relief valve-ok Check and clean pressure retrol-ok Check Automatic water feeder-ok Check Temperatures & settings-ok Flush boiler twice. Check and run Thermostat- operating Check and checked HWH. Check for leak, no leakage at this moment. Check gas control valve-ok Check safeties-ok Check air combustion and draft-ok HWH operating fine at this moment. Run and test system, runs fine, left system operating well at this time. -/-/-/-/- Note: I offer and provide information abou
Heating maintenance on x3 Amana Gas Furnace systems. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners, brush and vacuumed-ok Check and clean Air Filter- replaced. x2) 20x25x1 & 1) 20x20x1 Check and clean ignition Assembly-ok Check and clean- flame sensor-ok Check Safety Controls-ok Check CO2-CO- okay Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air, intake & exhaust lines-ok Check Temperatures settings Performance-ok Check and clean condensate water traps-ok Check and clean condensate pump- washed out. Check and run Thermostats- operating at this time. Inspected water heater Check for water leak- no leakage at this time. Check gas valve and gas Line-ok Ran water heater, operating well at this moment. Ran and monitored systems & left system operating well at this time. Recommending to customer to replace x3 air movement system standard duty
Completed hearing maintenance on one Burnham hot water boiler, which also supplies domestic hot water Removed and clean burners and igniter and flame section also clean burner tray Checked expansion tank turn system on and checked operations left system functional Also flushed domestic hot water tank
Performed heating maintenance on one burnham hot water boiler with indirect domestic hot water tank removed and cleaned the burners and the electronic spark igniter and checked electrical and mechanical components and connections also checked automatic flue damper and checked the expansion tanks also flushed the domestic hot water indirect tank and covered the condensers and turned the power off at the disconnect at the condensers checked boiler and domestic hot water left systems operational View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-6844012A1CCD4C488E74A1BD4F8E3A75
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-3DE5039F900D443897936FB980A12694 Customer has no heating in home from gas water boiler: * call for heating at thermostat at arrival * check boiler in basement * found that the circulator pump is on and running and the vent damper has opened but the igniter is not sparking pilot to light boiler * check safety’s and found system off on spill switch * reset spill switch and boiler fires- normal operations * immediately can feel back drafts from the boiler hood and exhaust spilling into boiler room * shut system down * disconnected flue piping to find chimney 90%+ plugged with debris- appears that the chimney has collapsed * show all findings to customer * reconnect flue piping and shut power and gas to boiler RECOMMENDED - to customer to contact Mr. Chimney to have the chimney inspected and recommended follow up maintenance after it’s repaired to insure normal operations