Richard with innovative air was great! Very prompt, communicated arrival time and sent updates and was extremely helpful and knowledgeable .
Overall Experience
Quality
Price
Convenience
Innovative and Antonio do not disappoint. Courteous, prompt, thoughtful and thorough. Know the work will get done with care. thank you!!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I returned to add a steam boiler treatment cleaner. I proceeded to drain the unit multiple times. I added clean water to the system. I proceeded to dilute the chemical to add it to the system. I concluded with the steam boiler cleaner. I showed it to the client and explained to him about the process carried out on this occasion. - Richard assisted the customer with a steam treatment for their boiler, explaining the process and guiding them through the steps. - The customer expressed a desire to learn how to perform the procedure themselves in the future. - Richard provided instructions on how to properly operate the levers and switches involved in the process. - The customer mentioned previous difficulties with the boiler, which Richard addressed by explaining the correct procedure. - Richard planned to add a steam cleaning treatment to the boiler and explained the expected changes in water color during the process. - The customer seemed satisfied with the assistance and the impr
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-82F76790F2AA48B59B6C0568A7D3ECCE Completed heating maintenance on two furnace removed and clean the igniters and the flame sensors also cleaned burner tubes replaced filter filters18+18+1 and16+16+1 also checked blower wheels and electrical components and mechanical components highly recommended to replace the neutralizer rocks for the system. Located in the basement systems are functional at this time. Left thermostat set to 98° as requested by homeowner left systems working
Checked first floor Trane air handler with hot water heating coil for no heat checked circulation pump and coil had to purge air out of the loop tested system operations left system working highly recommend to replace the automatic air vent on the return hot water line View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-B0A0BFA4A4284F63B37EA4A80D48A6DB
Gas Steam Boiler Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, vacuumed-ok Check and cleaned flame sensor & Pilot Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Flue Pipe-ok Check GVD- Flue Damper-ok Check LWCO-okay Check and cleaned pressuretrol pigtail-ok Check and make leak test-ok, it is not leak at this moment Check relief valve-ok Check and clean pressure retrol-ok Check Automatic water feeder-ok Check Temperatures & settings-ok Flush boiler twice. Check and run Thermostat- operating Check and checked HWH. Check for leak, no leakage at this moment. Check gas control valve-ok Check safeties-ok Check air combustion and draft-ok HWH operating fine at this moment. Run and test system, runs fine, left system operating well at this time. -/-/-/-/- Note: I offer and provide information abou
Heating maintenance on x3 Amana Gas Furnace systems. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners, brush and vacuumed-ok Check and clean Air Filter- replaced. x2) 20x25x1 & 1) 20x20x1 Check and clean ignition Assembly-ok Check and clean- flame sensor-ok Check Safety Controls-ok Check CO2-CO- okay Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air, intake & exhaust lines-ok Check Temperatures settings Performance-ok Check and clean condensate water traps-ok Check and clean condensate pump- washed out. Check and run Thermostats- operating at this time. Inspected water heater Check for water leak- no leakage at this time. Check gas valve and gas Line-ok Ran water heater, operating well at this moment. Ran and monitored systems & left system operating well at this time. Recommending to customer to replace x3 air movement system standard duty
Completed hearing maintenance on one Burnham hot water boiler, which also supplies domestic hot water Removed and clean burners and igniter and flame section also clean burner tray Checked expansion tank turn system on and checked operations left system functional Also flushed domestic hot water tank
Performed heating maintenance on one burnham hot water boiler with indirect domestic hot water tank removed and cleaned the burners and the electronic spark igniter and checked electrical and mechanical components and connections also checked automatic flue damper and checked the expansion tanks also flushed the domestic hot water indirect tank and covered the condensers and turned the power off at the disconnect at the condensers checked boiler and domestic hot water left systems operational View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-6844012A1CCD4C488E74A1BD4F8E3A75
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-3DE5039F900D443897936FB980A12694 Customer has no heating in home from gas water boiler: * call for heating at thermostat at arrival * check boiler in basement * found that the circulator pump is on and running and the vent damper has opened but the igniter is not sparking pilot to light boiler * check safety’s and found system off on spill switch * reset spill switch and boiler fires- normal operations * immediately can feel back drafts from the boiler hood and exhaust spilling into boiler room * shut system down * disconnected flue piping to find chimney 90%+ plugged with debris- appears that the chimney has collapsed * show all findings to customer * reconnect flue piping and shut power and gas to boiler RECOMMENDED - to customer to contact Mr. Chimney to have the chimney inspected and recommended follow up maintenance after it’s repaired to insure normal operations
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-1C340A7B1F534C8082C22D68172D691F
(1) AC Maintenance - UNICO -Upon arrival client mentioned that she won’t be on site until 9am. Checked condenser pressures checked fuse found fuse blown, supplied and installed 30 amp fuse, checked electrical compartment and cleaned, found pitted contactor and out of range capacitor, Supplied and installed Turbo Capacitor and Contactor at condenser, also installed Hard Start Kit and removed potential relay. Checked indoor unit, flushed drain line, checked evaporator coils ok, filter recently replaced. Started system, checked delta T ok, performed full condenser wash to remove dirt and debris from coils. Unit is now fully operational and cooling well. Reviewed all work completed with client, collected payment, emailed invoice.
Upon arrival set up Extension Ladder to access UNICO Air Handler, Checked Secondary Pan noticed pan filled with water, Vacuumed all of the water inside of pan, System was off on safety device, cleaned pan switch and tested ok, condensation line was also blocked. Blew out drain line and cleaned dirt out of condensation line, tested primary pan with water multiple times no leakage at this time, added Vent into Condensation line. Checked refrigerant pressures checked coils dirty must return to complete FULL Condenser Cleaning - checked delta T ok receiving good temp split, System is currently cooling and operational at this time. Follow Up Action: Return to Complete FULL Condenser Wash to remove debris and dirt build up and improve system performance. Office will follow up.
Service call for a/c not cooling on arrival the fuse at the condenser was checked and the fuse was ok. The thermostat is calling for cooling but nothing is run air handler is not running and condenser is also not running. The air handler is located downstairs in growlers bar. Two techs and an extension ladder is needed to access the air handler in the ceiling. Access is needed to air handler to further diagnose the issue further. This issue is not related to the fuse burning out. There is no voltage at the thermostat. No one was onsite at the time of the visit.
Service call for no a/c in dance studio 2nd floor suite. On arrival thermostat was set to 67 but reading 83 degrees. Found a bad fuse at the outdoor disconnect for the condenser. This fused was replaced and system started up. Checked refrigerant pressures, total amps and compressor amps. Pressure are good and system is back up and running. It is recommended to replace the fused disconnect to a regular disconnect and also to upgrade the breaker for the outdoor condenser. The current fuse is a 30amp and the max fuse can go up to 45 double 208. It is possible that the fuse burned out due to the system needing a maintenance also the location of the outdoor condenser is under a deck and with hot temperatures this could drive up the amperage causing the fuse to blow out. System is in need of a maintenance the air handler is located downstairs in the growlers bar. An extension ladder is needed and also two technicians. The tenant needs to speak with the landlord so we can coordinate acces
Today I arrived on site Initial Assessment: Determined the AC system was not working due to a full secondary drain pan. Problem Identification: Located the source of the issue: the EZ-Trap was clogged. Resolution: Cleared the clog in the EZ-Trap, resolving the drainage issue. Upon arriving at the property, the client explained to me that she noticed that the secondary drain pan was full of water. I proceeded to verify the tstat. The tstat had no power. I proceeded to check the AHU in the attic. I found the secondary drain pan full of water. I explained to the client that this water must be removed from the drain pan so that the pen switches return to normal and close the circuit. I presented him with the cost to remove the water from the drain pan. The client denied the proposal. The client said that she will remove the water herself. I ran water in the primary drain pan and checked for water leaks. The primary drain pan had no water leaks. I ran water into the condensate pum
Service call for issue with a/c that serves the main work out area of the gym. On arrival I spoke with Jackie and she had seen that the line set going out to the condenser was starting to freeze up so she had shut the system off. Air filter was very dirty this was replaced 20x20x1. System was turned on and all operations were checked. Found that the system is low on refrigerant causing it to freeze up. This is an indication that the system has a refrigerant leak. Explained to customer that there is a possibility of a leak and we would have to recharge the system up with refrigerant and add a dye to try and trace the leak. Once the dye is in the system we would have to return in 60-90 days to try and find where the system is leaking from. Unit could be leaking for either the indoor coil or outdoor coil or the line set. Jackie explained that I would have to email the owner to try and get approval. Nothing was done at this time and the system was left cooling off and fan on. https:/