View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-C423D1A2B819422DA12AECC7392951DD Perform maintenance on Goodman gas fired furnace with two zones: * power down equipment * Open furnace and blower cabinet doors * Both compartments and components are filled with debris and dust * Disassemble burner section of furnace, removing flame sensor, Hot surface igniter and burner tray * Vacuum and dusted out furnace cabinet and components, clean and clear * Vacuum and brushed out burner jets, clean and clear * Vacuum and dusted out debris from blower cabinet and components * Vacuum and dusted out filter rack on system * Vacuum and dusted furnace cabinet / Duct work and components, clean and clear * Clean the flame sensor with copper bristle brush and polished with steel wool * Inspected hot surface igniter: Showing heavy wear and replacement as recommended * Replaced and dated customer provided Aprilaire 413 air filter * Secured and inspected electrical wiring a
Standard duty electrical stored power boost system Upon arrival had thermostat call for cooling. Inspected indoor air handler. Blower motor is on/ running. Filter was replaced @ time of AC maintenance. Checked outdoor condenser. Outdoor system is not operating. System is heard struggling to try and start. Opened up electrical cabinet and found standard duty electrical stored power boost system swollen/ bulging @ top of booster. Gave customer estimate to replace booster. Customer agreed. Booster was replaced, system was ran and tested for normal operation. Low side pressure 125psi / high side 275psi View visual findings from this job here - https://visionshare.xoi.io/?id=XA-FA02-DE2FAEABEF694B70BE6566198A856579
Chemically cleaned evaporator coil. Inspected blower compartment and primary drain pan. Treated and cleared all drain lines,traps and tested all condensate pumps. Brushed and cleaned all electrical cabinets and tighten and secured all electrical connections on both inside and outdoor units. Tested all safety switches all in working condition. Replaced air filter provided by homeowner Aprilaire 210. Chemically cleaned outdoor condenser and checked operations and refrigerant pressures. Tested all electrical voltage, capacitors, and amperage on all motors and compressors. System is operating properly at this time. https://visionshare.xoi.io/?id=msa53bae28-575d-i184-bf994727b7b0-uF83-79cf6e4578b8