11 Kimball Place
Mount Vernon, NY 10550
914-793-7700

Local Reviews
for white plains, ny

Rated 5.0 out of 5 stars based on 9 customer reviews

Great Service

Prompt. Clear and concise explanations. Provided options. Courteous. Nice guy!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Gary did a great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Professional Service

Innovative Air is always reliable and professional Lorenzo and Gary provided great fall service in timely and knowledgeable manner.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Antonio S is a very impressive technician. He was able to diagnose the electrical problem in a very short time. He is a great asset to Innovative Air

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service and very high quality work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very pleased with this company

Took forever for us to decide to insulate our attic mostly because we had so much junk up there. But this group took everything away, put in new flooring and great insulation. We went from R11 to R42! What a difference. We set the thermostat to 60 at 9pm each evening but it never gets to that because the insulation does such a good job of keeping heat in. Also insulated where we had a frozen pipe situation and no frozen pipes this winter. Group very nice to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very knowledgeable company representative. The crew was on time and professional. The workmanship was very good . I am very happy and will definitely use Innovative Air Solutions again


Response from Innovative Air:

Thank you Chris for your feedback. Always happy to hear good things about our team. Please let us know if you need us in the future. We are always here to help. Thanks again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and very reasonably priced

Service was very good. The knowledge was exceptional and provided me with what was needed and what was not needed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for white plains, ny

Lorenzo M.

Lorenzo M. Job Checkin

I/W Upon arrival had customer run 1st floor/basement system. Check applied voltage. 244volts Check compressor amperage. 7.08-8.37 amps Fan is running @ higher amperage than factory rating of .93 fan motor is pulling .94-1.16amps Checked compressor windings with meggohmmeter to show compressor is good. Spoke with technician support. Technical support recommended that a crank case heater may be helpful once refrigerant charge is above 10lbs. technical support also mentioned that in some case based on thermostat that is being used we could get reverberations @ outdoor unit. System is working @ this time, issue is premature we’re unable to determine cause of condenser making screeching sound on shut down. Customer will monitor system operation. Manufacture is aware of this issue with 1st floor Trane condenser. Need to monitor system operation in the future. Issue may need to be revisited @ a later time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-48E7


Mark E.

Mark E. Job Checkin

Dirt accumulation on air movement system View visual findings from this job here - https://visionshare.xoi.io/?id=XA-853F-B6422A050E694186A3972FD7084F8732 Perform blower wheel and air movement rejuvenation for both first and second floor systems- Trane and Ameristar equipment: Shut Power to furnaces Open furnace and blower cabinet doors Disconnected and removed electrical control board and bracket from blower cabinet Disconnected and remove the limit switch from blower assembly Disconnected and removed capacitor from blower assembly Remove the blower wheels from blower motor shafts Removed blower motors from assemblies Brought indoor blower wheels, and assemblies outside- Chemically sprayed washed And rinsed blower wheels, and assemblies, clean and clear multiple times- polished and Dried vacuumed / dusted and polished blower motor cabinets clean and clear dusted and vacuumed motors clean and clear polished all wiring and secured connections installed blower wheels back into asse


Mark E.

Mark E. Job Checkin

Return to reclaim refrigerant, Repair leak on suction line at condenser, And full recommissioning: at arrival shut power to the system reclaim whatever remaining refrigerant was left inside the system remove core pins from service ports protect the suction line service valve in preparation for repair with torch, braze and repair leak at suction line outside preform nitrogen pressure test at 400psi on coil, line set and condenser check with bubbles to confirm no leaks and system holding at 400psi release all nitrogen from system place system into vacuum while system is in vacuum- removed panels of the condenser to expose the condenser coil- Coil and cabinet cabinets are dirty Chemically sprayed and washed outdoor condenser coil, Cabinets and fan blades, clean and clear Reassemble and secure all panels back onto condensing unit System and vacuum over one hour- holding install factory charge + additional for line set and coil totaling in 10lbs 9oz R410A cycle system on and off multiple t


Lorenzo M.

Lorenzo M. Job Checkin

Return to replace evap coil for 1st floor aspen air handler. Pump system down removed existing leaking coil. Installed new coil, pressurized system for leaks and pulled a vacuum. Charge was released and 2lbs of refrigerant was added to the system. Repair is completed system is operational. Customer left before we were finished but approved for us to use credit card on file. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-D939-18E17D72F61746E6831B2EDC3A819CA6


will@innovativeairsolutions.com

will@innovativeairsolutions.com Job Checkin

(1) TCC AC Maintenance - 410A - TRANE - Tested high and low voltage components ok, checked return grille and replaced 14x24x1 Filter provided by client, checked squirrel cage fan noticed blower wheel is extremely dusty and has heavy signs of growth build up. Blower must be removed and cleaned. Highly recommended for us to return for blower wheel cleaning ASAP. Checked evaporator coils and cleaned with evaporator spray and water. Tested primary drain pan with water multiple times no leakage at this time, tested condensation pump with water pump is operational no leakage at this time, cleaned out EZ Trap Safety with brush also cleaned Primary Pan, Drain is flowing freely with no blockage, Checked Condenser pressures, checked condenser coils ok. Sprayed and washed off condenser with hose. Checked electrical compartment and cleaned, tested compressor amps and blower amps, System is currently fully operational and cooling well at this time, Spoke to client about life expectancy of Air Condi


Nigel  B.

Nigel B. Job Checkin

Performed leak check on the first floor AC system with ultraviolet light and goggles found ultraviolet dye and refrigerant oil at the suction line at the condenser please see photos recommend to recover the refrigerant 410 and repair the leak and pressurize the system with nitrogen to check for pressure drop and then evacuate the system and recharge system with refrigerant 410A 8lbs condenser factor charge and top off system


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Service call for water near both furnaces in the basement mechanical room. On arrival homeowner explained that we had recently done the maintenance on both systems and she had found some water near the condensate pumps near the furnace. Both a/c systems drain into this pump. found that the condensate pump was not fitting on the base properly. Adjusted condensate pump and tested. Poured water in all drains did not find any leaks and pump is operating properly customer is going to keep an eye out for any further issues. https://visionshare.xoi.io/?id=msa7b6f0bd-575d-i184-a045457dbce5-uF83-75f1f05123e1


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Completed a/c maintenance on a unico air handler with a run tru outdoor condenser. Chemically cleaned evaporator coil. Inspected blower compartment and primary drain pan. Treated and cleared all drain lines,traps and tested all condensate pumps. Brushed and cleaned all electrical cabinets and tighten and secured all electrical connections on both inside and outdoor units. Tested all safety switches all in working condition. Replaced pristine air filter size 14x30 Chemically cleaned outdoor condenser and checked operations and refrigerant pressures. Tested all electrical voltage, capacitors, and amperage on all motors and compressors. System is operating properly at this time. https://visionshare.xoi.io/?id=msc26aa56d-575d-i184-7d57473995b2-uF83-8923a725e78a


Lorenzo M.

Lorenzo M. Job Checkin

AC Maintenance on x2 Ducted Mitsubishi Heat Pump system w/ x1 Condenser body Perform a tune-up and cleaning to help ensure reliable and safe operation on x2 indoor heads x1 outdoor condenser unit. Blower Motor – measure amperage and voltage for proper operation Thermostat – test for proper operation Clean existing air filters-cleaned and washed. Check and clean fan blower wheel-ok Clean indoor coil-cleaned and washed Clean Condenser Coil-cleaned and washed Flushed out drain line-ok Monitor refrigerant operating pressures-ok suction line: 125psi Liquid line: 350 psi Refrigerant type: 410A Electrical Disconnect Box – inspect for safe installation Electrical Wiring – inspect and tighten connections-ok Test/inspect contactors for burned, pitted contacts-good Inspect electrical for exposed wiring-good Inspect and test capacitors-good Inspect fan blade-ok Clean condenser coil and remove debris-ok Inspect service valves for proper operation-good Compressor – monitor and wiring connections-goo


will@innovativeairsolutions.com

will@innovativeairsolutions.com Job Checkin

(2) AC Maintenance - R22 - 80 Percent Furnace w/ Air Conditioning Coil - tested high and low voltage components, noticed multiple issues with system, noticed heavy signs of rust from interior of unit, flue piping, evaporator coils and blower housing. Tested both primary drain pan with water noticed 2nd fl system has small water leakage from system. Upon arrival found water near 2nd fl system. Checked each condensation pump operational at this time, noticed poly vinyl is loose and is not strapped near sump pump. Zip tied condensation line near sump pump, tested pump multiple times ok, checked each air filter recently replaced by client, checked delta T ok, noticed that 1st fl system ductwork is very dusty, highly recommended receiving duct cleaning, inspected both squirrel cage fan noticed both blowers are extremely dirty. Checked condenser pressures noticed 2nd fl system pressures slightly below normal for today’s weather 89F, system currently cooling checked electrical compartment on


Nigel  B.

Nigel B. Job Checkin

Performed comprehensive leak inspection with ultraviolet light and goggles and electronic leak detector equipment there is no indication of ultraviolet dye at this time took pictures of the refrigerant psi using analog gauge office personnel please follow up


Nigel  B.

Nigel B. Job Checkin

Completed maintenance on two Mitsubishi air handlers and one hyper heat Mitsubishi condenser checked electrical and mechanical components and connections and tested condensate drain with one gallon of water per system and treated drain pan checked system operations and left systems working note both systems filters are washable


Richard  .

Richard . Job Checkin

AC Systems. x2 Furnace units. x2 Condenser units. Today, I arrived on site to perform an A/C systems tune-ups and cleanings. Here's what I did: Checked the blower motor and thermostats for proper operation-okay. Air filter: replaced. x2) 14x24x1 Checked and cleaned the exterior jacket and interior cabinet-okay. Found the blower wheel-okay. Checked the ductwork-okay Washed and cleaned the indoor Evap coil. Checked and cleaned condensate pump and drain line, treating it with anti-algae. Monitored the refrigerant operating pressures-okay. The refrigerant type are 2x) R410A. Inspected the safety devices and found them to be operating properly. Inspected the electrical disconnect box for safe installation-okay. Inspected and tightened electrical wiring connections-okay. Tested and inspected the contact, which is not burned Inspected the electrical for exposed wiring-okay Inspected and tested the capacitors-okay. Inspected the fan blade-okay. Cleaned the condenser coil and removed debris. C


will@innovativeairsolutions.com

will@innovativeairsolutions.com Job Checkin

(1) AC Maintenance - BRYANT - R22 - Upon arrival had to wait until 8am to start due to no workmen in residence before 8. Tested high and low voltage components ok, checked indoor unit squirrel cage fan dusty recommended returning to clean, inspected evaporator coil and cleaned with chemical cleaner, tested primary drain pan ok at this time, tested condensation pump fully operational, noticed that suction line is not insulated and has been dripping on exterior of furnace for some-time, checked control board ok at this time, checked indoor capacitor within range, checked delta T ok receiving good temperature split, checked condenser pressures ok, checked electrical components at outdoor unit ok at this time, cleaned interior of condenser electricals, brushed and chemically washed condenser coils with clients hose, cleaned exterior of unit, reviewed all work completed with client, collected payment, emailed invoice. Unit is currently operational and cooling at this time.


Nigel  B.

Nigel B. Job Checkin

Performed maintenance on one Mitsubishi condenser and two Mitsubishi ducted air handler with branch box checked electrical and mechanical components and connections and flushed and tested condensate drain lines also checked blower wheels and evaporator and condenser coils turned systems on and checked operations left system working