Lorenzo M.

Lorenzo M. Job Checkin

Here to replace installed Evaporator coil for 2nd floor system. 2nd floor system had a leak in evaporator coil. Unit was completely flat. Pulled vacuum on remaining gas to Unsweat brazing joint to disconnect line set from old existing evaporator coil. Disconnected drain, remove line set. Needed to re-hung hanging material to support new coil and reposition drain pan. Disconnected return flexible ductwork to remove coil. Installed new coil, brazed in line set and level unit and reconnected drain line and return ductwork. Pressurized unit with dry nitrogen to 350psi and let sit for 30 minutes to a hour. System pressures held, no leak. Dump dry nitrogen and a pulled vacuum on system for 30minutes to a hour. Added 7lbs of R410A refrigerant charge to adjust system pressure and temperature. Ran and test system operation. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-99B16F2771B74540B06B30D2FE173CBC


Richard  .

Richard . Job Checkin

Today I arrived on site to address the dye leakage issue in the AC system. Diagnosis and Findings: Identified multiple dye leaks within the cooling module of the 2nd floor AC system. Recommended Action: Replacement of the cooling module is necessary due to the extent of the leaks. When arriving at the client's property. The client explained to me that another company had done a dye test. The company previously diagnosed an R410A leak in the cooling module of the 2nd floor system. I proceeded to verify the system. I found multiple dye leaks in the evap coil. I proceeded to check the condenser coil. I didn't find any leaks in the condenser coil. I showed him to the client and I explained about the situation of the system. I explained that I will submit the information to the office so that he can be contacted to provide you with updates on the replacement of the cooling module. I also recommended the client who should consider scheduling appointments to do the tuneups. View


Mark E.

Mark E. Job Checkin

Preform maintenance on (1) Ameristar gas fired furnace: * show power to furnace * Removed blower and furnace cabinet doors * Removed flame sensor and hot surface igniter * Clean flame sensor with copper bristle brush, and polished clean with steel * Inspected hot surface igniter- Showing heavy and replacement was recommended- Customer does not want to move forward with it at this time * Vacuum and dusted out furnace cabinet and components * Vacuumed and dusted out blower cabinet and components * Removed all burner jet and brushed and vacuumed clean * Published and wipe down all equipment in furnace and blower cabinet * Secured electrical wiring and components * Inspected flue, piping and fresh air intake * Flushed condensate tubing and trap for high-efficiency furnace * Replaced 18 x 25 by one air filter provided by customer * The customer replaced his own humidifier water panel and does not want me to service it at this time * Reassemble furnace, securing oil connections, and return


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-6DFE29F0AFA34445A49410C7CCE05C52 Perform maintenance on three zone well McLean boiler: * At arrival, the power to the boiler is off at the switch * The customer stated that he had a contractor replaced two circulator pumps and add an additional baseboard zone to the basement * The customer did not trust the contractor and believes that there is an air in the system * The boiler is old and outdated, and has been neglected and covered in dust debris * Remove boiler door shut down gas valve * Remove flame, guard, and all burner tubes from boiler * Vacuum and dusted out lots of debris from burner section under heat exchanger * Vacuumed and brushed all burner tubes, clean and clear * Vacuum and dusted boiler cabinet, Components and oil piping * Test and inspect water feed / Backflow / Expansion tank air vent and relief- okay * Confirm boiler pressure is normal * Thermocouple is showing heavy signs of wear an


Lorenzo M.

Lorenzo M. Job Checkin

Standard duty electrical stored power boost system Return to replace 1st floor evaporator coil and TXV Manually pump system down. Unsweat line set Cut PVC drain pipe to remove evaporator coil. Install new evaporator coil and TXV. Brazed in line set. Re-installed pvc drain line. Pressurize system with dry nitrogen @ 350psi for 45 minutes. No leak. Remove dry gas Pull vacuum @ system for 45 minutes. No leak. Let vacuum sit for 5 minutes Ran and test system operation. Recommend to customer to replace standard duty electrical stored power booster for 1st floor system due to rust and corrosion @ booster. Customer agreed. Booster was replaced. System is back up for normal operation @ this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A3D0-94C3DB60DB3349ACA2BA94137464FD17


Lorenzo M.

Lorenzo M. Job Checkin

Performed AC maintenance on x2 system. x1 R-22 system for basement x1 Conventional system Chemically clean evaporator coil Chemically treat pans with slow release tabs and gel treatment Flush condensate pans and drain lines Replace pristine filter for x2 system… Needed to order new dynamic pads for customer x2 Visually inspected ductwork for leakage and breaks Clean return grill on second floor Inspect thermostat operation Inspect blower motor and housing for dirt and debris Inspect and test safety switches Inspect and test condensate pump Inspect and test electrical connections Tighten and secure low voltage controls and connections Check temperature split @ equipment Wipe down and polish cabinets Chemically clean condenser coil Check Freon pressure and temperature Inspect and test capacitor/ check for swelling or pitting Inspect and test contactor/ check for burn out or pitting Inspect and test compressor amperage Inspect and test system voltage Clean indoor electrical cabinets Check


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Completed a/c maintenance on two central a/c systems two adp air handlers with two carrier outdoor condensers. Chemically cleaned evaporator coil. Inspected blower compartment and primary drain pan. Treated and cleared all drain lines,traps and tested all condensate pumps. Replaced air filters 16x25x4 and a pop up 2025. Brushed and cleaned all electrical cabinets and tighten and secured all electrical connections on both inside and outdoor units. Tested all safety switches all in working condition. Chemically cleaned both outdoor condenser’s checked operations and refrigerant pressures. Tested all electrical voltage, capacitors, and amperage on all motors and compressors replaced one of the capacitors on one of the outdoor units. Both units are operating properly at this time. Recommendations: duct cleaning on both units View visual findings from this job here - https://visionshare.xoi.io/?id=XA-6E0E-1773EB51EBC64205A45235529BA5123A


Lorenzo M.

Lorenzo M. Job Checkin

Upon arrival inspected 1st floor coil. Found dye trace on U Bend of evaporator coil. Inspected condenser coil. Remove fan motor to thoroughly check coil. Did not find any signs of dye trace @ condenser coil at today’s inspection. Explained to customer the possibility of dye showing up @ a later time. Condenser dye search is inconclusive @ the moment. System was ran and checked for normal operation. Whoever customer is aware that he needs to replace evaporator coil. Today’s pressure reading: Low side 125psi / High side 250psi Office to follow up to provide customer with a quote to replace his 1st evaporator coil View visual findings from this job here - https://visionshare.xoi.io/?id=XA-FA02-2A7FB89A75D2420AAC561A2C3C0A28E1


Nigel  B.

Nigel B. Job Checkin

For condensate pump for the AC in the basement Parts replaced on this visit. -x3 starter caps. -x1 contactor. -x1 condenser deep cleaning.


Michael C.

Michael C. Job Checkin

Repair no heat on Trane master bedroom furnace.


Michael C.

Michael C. Job Checkin

Install who house humidifier.


Michael C.

Michael C. Job Checkin

Trane A/C replacement

Trane A/C replacement Trane A/C replacement

Mark E.

Mark E. Job Checkin

Water leaking in basement

Water leaking in basement

Mark E.

Mark E. Job Checkin

Noise from HVAC

Noise from HVAC

Antonio S.

Antonio S. Job Checkin

No heat

No heat