Today I arrived on site Boiler Inspection:Addressed the "no heat" issue. Confirmed the boiler was not working. Heating System:Identified the zone as the heating system. Pilot Light Issue:Found the pilot light was off. Relit the pilot light. Leak Repair:Fixed water leaks at the shut off valves. Upon arrival at the property, the client was not in the property at the time of my arrival. I contacted the client, the client gave me access to the basement from the garage. The client explained to me the situation with the system and some repairs made recently. I proceeded to verify the system. I found the the pilot light went out. I proceeded to verify the pilot assembly. Relight the pilot. I started and monitored the system for a few minutes. The pilot did not fail during monitoring. I found some water leaks from the shut off valves of the system. I concluded with the system repairs. I contacted the customer and explained the results of the repair. I ran and monitored the system f
Return for recommended upgrades / Repairs: LIVING ROOM ANS KITCHEN AIR HANDLERS IN BASEMENT: * shut power Two equipment * Blower cabinet doors on both air handlers * Install and secure overflow pan safeties to both the living room and kitchen overflow pan * Install pump pan underneath condensate pump * Install and secure safety switches (2) Inside of pump pan for each air handler * Run low-voltage wire from inside electrical panel of air handlers two pan safety switches outside * Strap, all wiring, neat and clean * wire in pan safety’s at switch’s and inside air handlers breaking R power wire * Clean and pack up all garbage from basement * Review newly installed safeties and overflow pan with customer * Return power to air handlers * Test system operations: Call for heating at thermostats and confirm that Hydro coils are hot and blower motors are on and running * All pan safety switches were tested And are operational CONDENSING UNITS FOR MASTER BEDROOM AND SECOND FLOOR: * Replace ca
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-AC4C-DC0D12C9D9D94417A33D115C20F78B62 Preform maintenance on (4) Aspen hydro air handlers with (4) Goodman condensing units controlled by Honeywell WiFi thermostats : Filters : Aprilaire 210 (x4) open air handler cabinet doors Remove dirty air filters Installed and dated (4) Aprilaire 210 air filters in each air handler Chemically sprayed brushed and rinsed, evaporator coils, clean, and clear from both sides Chemically sprayed and wiped Primary pans, clean and clear Chemically treated primary pans and added condensate tablets Brush, drain lines and traps, clean and clear and blew out all drain lines Flushed and tested all drainage with freshwater: All water is falling from inside Primary pans through drain lines into traps and Out gravity, drain lines / into pump Flushed and tested gravity drain lines, Condensate pump and discharge line multiple times to ensure normal operations and no leaks Chemically spraye
Replacement of Amana Heat Pump and Central Air Conditioning System!