Excellent service, very courteous, and thoroughly professional. Highly recommended.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Over all experience was excellent and all questions were answered.
Overall Experience
Quality
Price
Convenience
AC went done over the holiday weekend. Made the call and a tech was at my hours in under 2 hours. He and his partner thoroughly reviewed my system, got it up and running and noted some other work tat should be done immediately.
Overall Experience
Quality
Price
Convenience
I like Gary. He knows my house and I trust him and the service he provides.
Overall Experience
Quality
Price
Convenience
Service Tech Antonio was thorough with his work. He seemed very knowledgeable. He explained what the problem was and was quick to perform a temporary fix while having to wait for parts to be ordered.
Overall Experience
Quality
Price
Convenience
To replace the thermocouple Perform maintenance on one Burnham hot water boiler removed and clean burners and standing pilot assembly replaced thermocouple checked expansion tank and pumps. Also performed combustion analysis left system working.
Arrived at location and found a gas fired heating system age of system unavailable did not provide service for diagnostic due to innovative air does not work on this type of equipment for safety issues ensured power supply is off and also the gas supply is off spoke with office personnel and was informed we do not work on this type of system highly recommended a replacement of the system with a new system was informed by office personnel that there will be no charge for the visit spoke with Mr David and he requested someone from the office to call him about options for a replacement View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-59CC0D314D844181BCB72926AA0F9898
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-1423F8DF26BC4856B69E1990EE5594E5 boiler is 14 years old emailed the option for the replacement of the igniter/flame rod
Perform maintenance on Trane gas fired Furnace: * Replaced and dated customer provided 16 x 25 by one air filter * Shut power to equipment * Removed furnace and blower cabinet door doors * Remove burner cabinet door * Remove flame sensor, Hot surface igniter and all burner jets * vacuumed and brushed all burners clean and clear * cleaned flame sensor with copper bristle brush and polished with steel wool * inspected hot surface igniter- almost 6 years old and showing signs of ware * vacuumed and dusted out burner section on furnace * cleaned debris from fresh air intake * flushed condensate tubing and trap on furnace- Hot water flowing through neutralizer kit into condensate pump * Tested condensate pump and discharge line multiple times to ensure normal operations and no leaks * Neutralizer minerals were recommended to be replaced, but customer does not want to move forward at this time * preform powder cloud test on heat exchanger- ok no blow back * reassemble furnace and component
Performed maintenance on one Lennox gas fired furnace checked electrical and mechanical components and electrical connections cleaned burners and igniter and flame sensor also checked blower wheel and air pressure switch and safety turned system on and checked system operation and checked for carbon monoxide none found and left system working View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-887D7D08F4324A1982223B09A47AE7EF
Perform heating maintenance a High efficiency water boiler unit. X1 boiler unit. X2 AHUs Hydro air handler. X3 indoor heads Heat pump systems. x1 condenser unit heat pump. Boilers : shop power to boiler Removed boiler covered doors- system, full of dust and debris Vacuum and dusted out boiler cabinet and components, under heat exchanger. Removed pilot assembly, and spark igniter from boiler Clean spark igniter and flame sensor with copper bristle brush, and polished clean with steel wool Reinstalled and secured all connections Test expansion tank, water feed, and backflow preventer, air vent, and relief valve- okay Secured and inspected electrical wiring and components Inspect flue piping and circulated pumps - okay Polished and wiped down all equipment Clean and washed condensate pump Clean and washed boiler condensate trap Return power to system Test take zoning panel, securing all connections- test Hydro and radiant heating thermostat- zone panel response, circulator pumps on and
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-AB08-815C456274464F2D81EF97CD2CFAF0F5 Preform heating maintenance on Burnham gas fired water boiler: shut power to boiler removed boiler covered door Found inside of the boiler cabinet and components, completely covered in sheet rock, dust and debris Found the firewall on the left side of the boiler had fallen over and was laying on top of the burners Remove the flame guard and rollout switch Remove all burner tubes Removed spark igniter- Cleaned with copper bristle brush, and polished with steel wool vacuumed and brushed all burner tubes, clean and clear Vacuum and dusted out burner section of boiler under heat exchanger Vacuum and dusted boiler cabinets piping and components Confirm boiler pressure is normal at 20 psi Test and check expansion tank, Water feed and backflow, And relief valve- okay Secured all electrical wiring, and components and dusted clean- blew out while vacuuming dust Secured firewall on
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-AB08-D4B2F429A24A4B0695633C0D9E2F2AFA My Perform maintenance on one Burnham gas fired water boiler with six zones and four Trane Hydro air handlers with UV light kits: CUSTOMER ALSO STATES THAT TWO OF HIS CENTRAL AIR SYSTEMS ARE NOT WORKING - BASEMENT AND FIRST FLOOR OF HOME -GAS WATER BOILER: Shot power to boiler Removed flame guard, Rollout switch, And all burner tubes and shut down pilot at gas valve Inspected heat, exchanger, piping, and damper motor-okay vacuumed and dusted out burner section of boiler under heat exchanger Vacuum and dusted out boiler piping cabinets and components, clean and clear Inspected thermocouple- Showing heavy wear and replacement is recommend- Customer approved Removed existing thermocouple from inside boiler and installed a brand new securing in gas valve and pilot assembly Brushed out and vacuumed all burner tubes, clean and clear Reinstalled all burners and relight pilot-
1 Gas Hot Water Boiler: Burnham Steam Boiler- w/ Hot water loop for 1st fl BB-Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners tubes and heat exchanger- ok, vacuumed-ok Check and clean flame sensor/flame rod and ignition Assembly-ok Spark igniter. Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Exhaust-ok Check Temperatures & Water pressure settings; Performance-ok Check and run Thermostats- operating well at this time. Check zoning operation-isolate and run zoning. Check circulation pump-ok amps and voltage check. Check water feeder, low water cut off, relief valve and expansion tank. Check for water leak no leakage at this moment. Run and monitored for good operations. All zones are fine supply and return lines getting hot. Check Aquastat relay, Automatic feeder and Automatic shut-off. Flush boiler 5-7 times. Cu
Heating Maintenance on x4 Mitsubishi Ductless Systems Heat Pump. Perform a tune-up and cleaning to help ensure reliable and safe operation on x4 indoor heads x2 outdoor condenser unit. Blower Motor – measure amperage and voltage for proper operation Thermostat – test for proper operation, calibrate and level-ok Clean existing air filters-cleaned and washed. Check and clean fan blower wheel-ok Clean indoor coil-cleaned and washed Clean Condenser Coil-cleaned and washed Flushed out drain line-ok Monitor refrigerant operating pressures-ok suction line:125psi Refrigerant type: 410A Electrical Disconnect Box – inspect for safe installation Electrical Wiring – inspect and tighten connections-ok Test/inspect contactors for burned, pitted contacts-good Inspect electrical for exposed wiring-good Inspect and test capacitors-good Inspect fan blade-ok Clean condenser coil and remove debris-ok Inspect service valves for proper operation-good Compressor – monitor and wiring connections-good Systems
OFFICE TO FOLLOW UP WITH CUSTOMER TO GIVE QUOTE FOR UNLISTED ITEM AS WELL AS TO SCHEDULE REPAIR Upon arrival inspected air handler in the attic for 2nd floor. Found evaporator coil frosting up. Needed to defrost coil before I could proceed to check system operation. Remove zone damper to check zoning operation. Need to verify that zone dampers are opening and closing on call. Remove all x3 dampers from ductwork and had thermostat call for cooling. Dampers open and closing on call normally. When system is calling for cooling. Condenser is short cycling. Shut system down and remove sensing build from suction lines. Installed sensing bulb in hot water to force metering device open. System began to operating as it should. Pressure are stable: low side pressure 125psi / high side pressure 310psi system is no longer short cycling when sensing bulb is remove from suction lines. Supply temp is 54F degrees return temp 75F degree System has a bad metering device that needs to be replaced. Meter
Here to replace main house water filtration filters. Shut main valves, open up bypass. Decompress water pressure @ filter tank. Remove tanks to replace filters x2 Install new filters provided by customer. Reconnect tanks. Shut bypass and reopen main water valve. Water filtration is back up for normal operation. Notice calcium build up @ mixing valve for indirect storage tank. Calcium build up could lead to the possibility of a leak. Explained to customer that the mixing valve may require to be replaced in the near future to prevent any water leakage. Customer will monitor valve @ this time, further action maybe required. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-0013-773C3CAA2A9643C8AF633009184DBB2D
Here to replace ECM blower motor for 2nd floor system. Remove screws from housing and disconnect electrical wiring @ motor to remove blower motor and assembly from cabinet. Removed old blower motor from assembly. Installed new blower motor. Adjust rotation to confirm no fringing noise from motor rubbing on housing. Installed blower motor in cabinet and secure electrical wiring. Ran and tested blower to confirm motor in back up and running. Switch thermostat from fan on to have system call for cooling. System is on running took temperature split @ equipment for supply and return. Supply temp 56.8F degrees return temp 78.8F degrees. To confirm AC system was back up to normal operation, check outdoor unit to make sure pressures were ok when I discovered that the system is short cycling @ 2nd floor condenser. Refrigerant line is frosting up and pressure is low @ 2nd floor system. There's a possibility of system having a leak or a restriction. Suction line pressure is 50psi over high side o
Arrived to property. Ring doorbell to get no answer. Called customer, got no answer. Left vm for customer to call me back. Gave customer grace period of 15-30minutes as a courtesy. Still no call no show. Office or customer to reschedule service
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-7DDBCE354D2A4CD5891D2ABFF45BDE9E Preform maintenance on (2) zone heating w/ DHW Aulta High efficiency gas water boiler: * shut power to system * open boiler cabinet doors * removed flame rod and spark igniter: Cleaned with copper bristle brush, and polished with steel wool- Reinstalled and secured in place * Removed bottom of neutralizer trap and washed clean * Removed tube and flush condensate trap and prime with fresh water * Removed neutralizer condensate pump * Dump old minerals * Wash inside of condensate pump, clean and clear * Install new neutralizer minerals provided by customer * Reassemble and secure pump back in place and test operations multiple times to ensure no leaks- okay * Secured and inspected electrical wiring, Connections and components * Tested and inspected water feed/ Back flow, Expansion tank, Spiral vent and relief valve- okay * Confirm boiler pressure is normal * Cleaned out ins