Excellent service, very courteous, and thoroughly professional. Highly recommended.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Over all experience was excellent and all questions were answered.
Overall Experience
Quality
Price
Convenience
AC went done over the holiday weekend. Made the call and a tech was at my hours in under 2 hours. He and his partner thoroughly reviewed my system, got it up and running and noted some other work tat should be done immediately.
Overall Experience
Quality
Price
Convenience
I like Gary. He knows my house and I trust him and the service he provides.
Overall Experience
Quality
Price
Convenience
Service Tech Antonio was thorough with his work. He seemed very knowledgeable. He explained what the problem was and was quick to perform a temporary fix while having to wait for parts to be ordered.
Overall Experience
Quality
Price
Convenience
Checked second floor system found thermostat set to 62 and room temperature was 64 set thermostat to 74 and checked system operation system is working at this time but recommend to replace the thermostat
Return to replace hot water heater. Cut out and removed existing water heater installed a brand new 50 gallon gas water heater. After installation all connections were checked for water leaks and no leaks were found. Gas line was tested and no leaks are present. filled tank and fired up the burner. Monitored system until satisfied and all faucets and showers were bled. A co detector was installed in the boiler room. System is fully operational repair is completed.
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-D1A87BF33B0D458A95259D1D934D92B7 Customer has a leak from his gas water boiler, which he believes is coming from the pressure relief valve: * At arrival check the boiler in the basement * System is on standby with no active call * confirm boiler pressure and temperature is normal * call for heating at thermostat- monitor pressure and temperature with water feed closed * within minutes boiler pressure is rising past 25 psi - the expansion tank is filled with water and has gone bad * quote customer on replacement of expansion tank- he approved * shit down boiler and isolate expansion tank * removed the existing expansion tank from the boiler supply piping * installed and secured brand new expansion tank in place - open valve back to tank and adjusted pressure- confirm no leaks * return water feed valve back to open position and return power to boiler * vent damper opens, igniter sparks pilot and boiler fi
Customer has no heating from (2) zones in home ( first floor and master bedroom ) * at arrival thermostats are calling for heating and the indoor temp is below the set point * the air handler blower motors are on and running but blowing cold air * check boiler : zones 2 and 4 on Taco panel : circulator pumps are on and running * supply piping on top of pumps are cold indicating hot water is not circulating properly * explain to customer that it appears the zones are air bound and quoted repair which customer approved * shut power down to boiler * isolate heating zones and purge air from zones until coming back hot * return power to boiler and open all zones back up * test system operations for first floor, master bedroom and all additional zones * boiler fires- circulator pumps are on and running and all supply and return piping is heating properly * monitor boiler pressure and temperature- okay When preforming repair notice that the water feeder is extremely hard to lift up and is ge
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-0BACCF6ED27E4C5C955776D80B1AE581 Perform maintenance on one carrier and one Goodman gas fired furnace: * replaced and dated completely Plugged 18 x 18 x 1 and 16 x 24 by one air filters * Vacuum and dusted out return boxes * Vacuum and dusted out blower cabinets and components, clean and clear * Vacuum and dusted electrical components and wiring, clean and clear * Vacuum and dusted blower motors, and assemblies, clean and clear * Vacuum and brushed out furnace cabinet and components * Vacuum and brushed out burner jets * Clean flame sensors with copper bristle brush, and polished clean with steel wool * Inspected hot surface igniters- okay * Inspected blower wheels- slightly dusty * Secured and inspected all electrical wiring, and connections * Secured and inspected all safety switches * Tested thermostats, and call for heating- Inducer motors on, Pressure and limit switches close, Igniter glow up, Gas v
Check carrier gas fired furnace 18 years old diagnose system is not turning on due to one fan in the can is not sending 24 volts From the air proving switch also further diagnostics proves the gas valve is not opening even after 24 Volts is Is applied after jumping out 24 V from the air proving switch located in the Fresh air intake also known as fan in a can recommendations are replacement of fan in a can and replacement of the gas valves Due to age of system, highly recommend a replacement Please see photos for details office personnel please follow up with the homeowner for a quote on gas valve and fan in a can replacement View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-AA0F450F106A4B4CBA3E25449FE70715 left power supply and gas valve off as safety precautions
Completed check off water leak coming from expansion tank. Expansion tank is leaking and will have to be replaced Isolated expansion tank and removed water from tank EX-30 View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-7655BDDF774244F2B2CF2ADEAE95711F To replace the expansion tank.removed defective expansion tank and installed new expansion tank turned system on and checked operations left system working
Heating maintenance on x2 Gas Furnace systems. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners, brush and vacuumed-ok Check and clean Air Filter- replaced. x1) 16x25x1 x1) 12x20x1 & x2) 12x12x1 Check and clean ignition Assembly-ok Check and clean- flame sensor-ok Check Safety Controls-ok Check CO2-CO- okay Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air, intake & exhaust lines-ok Check Temperatures split Performance-ok Check and clean condensate water trap-ok Check and run Thermostats- operating at this time. Ran and monitored system, left system operating well at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-B0CE1269C8814282A6EF7B2CE4216BCE
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-C5676B69225148479692F3F2BC78B66E
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-7C8A3CE6F53F4D64B1F8957FD364C4C9 Return to replace pilot assembly ( flame rod and spark igniter) on Burnham gas fired water boiler: shut power down to system at arrival removed boiler cover door removed flame guard and roll out switch confirm that the existing igniter and new are like for like- correct components disassembled the pilot assembly and removed from boiler removed the old pilot assembly from burner and disconnected electrical from sense and igniter terminals installed and secured brand new pilot assembly ( igniter / flame sense ) to burner tube reassembled and install brand new pilot assembly and all burners back in boiler connecting back to gas valve- check for leaks- none reinstalled flame guard and roll out switch connect new electrical back to sense and igniter terminals return power to boiler call for heating- igniter sparks pilot and main burner fires- normal operations cycle boiler on
Today I arrived on site to address a water leak and parts replacements in the heating system. Repairs Completed: Addressed the water leak issue. Repaired the Exp-30. Repaired the Auto feeder with back-blow. Repaired the Relief valve. Upon arrival at the property. The BSM's rennet gave me access to the boiler room. I contacted Miss Jessie to inform her about the repair scheduled for this day. The client confirmed the aforementioned repair. I proceeded to clean the work area. I proceeded to drain the system to disassemble the defective parts. I concluded with the dismantling of the defective parts. I proceeded to install the new Exp-30 in the system. I proceeded to install the new Auto Feeder with the back-flow prevent on the unit. I proceeded to install the new relief valve in the unit. I secured and tightened the pieces installed on this occasion. I proceeded to fill the system with clean water. I proceeded to bleed the x5 areas of the system one by one. I concluded with the bleeding
Igniter/flame sensor replacement Arrived at location and attempted to replace nighter/flame sensor upon removal of old igniter/flame sensor discerned. It is the wrong igniter/flame sensor. Replaced old flame sensor/igniter turn system on and checked natural gas lines. No leaks left system working please see photos of equipment, data and model and serial number off the control module. Also there are photos of both igniters/flame sensor. The one on the right is the Igniter/flame sensor that is needed
Gas Steam Boiler Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, vacuumed-ok Check and cleaned flame sensor & Pilot Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Flue Pipe-ok Check GVD- Flue Damper-ok Check LWCO-okay Check and cleaned pressuretrol pigtail-ok Check and make leak test-ok, it is not leak at this moment Check relief valve-ok Check and clean pressure retrol-ok Check Automatic water feeder-ok Check Temperatures & settings-ok Flush boiler twice. Check and run Thermostat- operating Check and cleaned x2 HWH. Check for leak, no leakage at this moment. Check gas control valve-ok Check safeties-ok Check air combustion and draft-ok HWH operating fine at this moment. Run and test system, runs fine, left system operating well at this time. -/-/-/-/-/- Gas Hot Water Boiler. Perform a tune
Hight Efficiency gas boiler/AHUs X1 Gas Boiler. X1 Indirect hot water tank. X4 AHUs / Hydro coils. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners an heat exchanger- ok, vacuumed-ok Checked and cleaned flame sensor and ignition Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Exhaust, intake lines-okay Check GVD Damper-N/A Check Temperatures & Water pressure settings; Performance-ok Check and run Thermostats- operating well at this moment. Check and clean condensation trap of the boiler-ok Perform inspection on a DHW tank. Check for water leak, no leakage at this moment. Check water valves-ok Check line-ok Check ST-12 exp- okay Check Aquastat-okay Check circulate pump-okay Run and monitored for good operation-ok Perform maintenance on air handlers Check fan blower motor-ok Check electrical wiring a
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-D0EB7B08826549B98603D00C71610DE9 Preform maintenance on Goodman gas fired furnace: * shut power to system * removed furnace and blower cabinet doors * removed flame sensor and hot surface igniter * Disassembled furnace tray, roll out switch’s and all burner jets * vacuumed and dusted out furnace cabinet and all components * vacuumed and dusted out filter cabinet and all components * vacuumed and dusted out filter rack and return box * vacuumed and brushed all burner jets clean and clear * polished inside blower and furnace cabinet * reinstalled all burners, furnace tray with roll outs, cleaned flame sensor with copper basil, brush, and polish clean with steel wool And reinstalled * Inspected hot surf igniter- Showing heavy wear and replacement is recommended- Provide customer with a quote while on site * Inspected flue, piping, inducer motor and assembly- okay * Secured on, inspected all electrical wirin