Nigel  B.

Nigel B. Job Checkin

Checked hot water radiator located in the first floor bathroom found system air bound purge system off air and system is functional left system working View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-564503F0E23243D3BEF6ED73231BE735


Nigel  B.

Nigel B. Job Checkin

Removed defective module for system 2000 hot water boiler installed new module and program as per manufacturers specifications turn system on and check operations on all three heating zones also checked domestic hot water indirect tested all systems Left system functional office personnel please follow up with the homeowner about the billing homeowner has questions regarding the billing and a maintenance agreement


Richard  .

Richard . Job Checkin

Today I arrived on site Issue Addressed: Addressed the reported heating issue on the 2nd floor. Problem Identified: Discovered air trapped within the 2nd-floor zone's heating system. Action Taken: Bleed the air from the lines. Current Status: The heating system is now operating normally. Upon arrival at the property. The client mentioned that a new tstat was recently installed on the 2nd floor. The client said this area is not heating up. I proceeded to verify the tstat. The tstat is working well at the moment. I proceeded to check the system in the basement. I found that the area of the 2nd floor had no water movement in the lines. I checked the CPump for proper functioning. The circulate pump is working well. I found that this area had air in the lines. I proceeded to bleed the area of the 2nd floor. I concluded with the bleeding of the area. The 1st floor area and the basement are heating up well at the moment. I concluded with the system verifications. I started the


Richard  .

Richard . Job Checkin

Today I arrived on site to address issues with the heating system. Heating System: Identified the control module as faulty. Determined the control module must be replaced. Upon arrival at the property. The customer explained to me that the boiler is turning on and off constantly. The customer said that another company verified the system. The customer was told that the ignition module had to be replaced. I checked the system, found the boiler modulator control is not working properly. The circulate pump is constantly running. The module because of the defect it presents is activating the CP constantly. I showed and explained to the customer that this module must be replaced. I explained to the client that I would submit the information to management to verify the availability of this piece. This boiler from 2002. It is possible that the parts of this unit are discontinued. The customer has Heat for the moment but the boiler is showing failures due to the malfunction of the module


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-AC27A976FC064DC792B9D624FEC517A The daikin heat pump For the upper level is not working properly- The system is off at the thermostat when I arrived at the home- I proceeded to verify multiple things on the system * Replace the 14 x 25 by one air filter in the return grill * Both side sides of the evaporator coil are cleaner and clear with no obstructions * Confirm proper airflow through the return ductwork * Confirm proper airflow through supply ductwork * Confirm no obstructions in air handler or blower cabinet * Check outdoor condensing unit- no active faults * Connect gauges to outdoor condensing unit * Call for heating on the Honeywell thermostat * Heat pump system is on and running * Monitor refrigerant pressures and temperatures, Airflow and temperature splits- okay * Perform static pressure test on ductwork- ok * Monitor operations: after the system has been running for over 35 minutes notice h


Nigel  B.

Nigel B. Job Checkin

Please see XOI for details View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-60F3516CB8E9472E8562A480C45542BD


Richard  .

Richard . Job Checkin

See Julio’s Notes for better information. Julio will be in charge of collecting the pending balance of this installation of a new AO Smith 50 gals HWH.


Mark E.

Mark E. Job Checkin

Preform maintenance on gas fired water boiler with (3) heating zones: * shut power to boiler * Shut pilot off at gas valve * Removed flame, guard, and rollout switch * Removed all burner tubes and pilot assembly from boiler and gas valve * Inspected heat, exchanger and flu piping * Vacuum and dusted out burner section under heat exchanger * Vacuum and dusted boiler cabinet and components, clean and clear * Vacuum and dusted boiler, piping and components, clean and clear * brushed out and vacuumed all burner tubes, clean and clear * Recommend thermocouple replacement- Customer approved * removed existing thermocouple- preform full maintenance on pilot assembly * installed brand new thermocouple securing in gas valve and pilot assembly- Check for leaks- None * Reinstalled all burner tubes, flame, guard, and rollout switch * Secured and inspected all electrical wiring, and components and polished clean * Test and inspect system expansion tank, Water feed and backflow preventer, Air vent


Richard  .

Richard . Job Checkin

Today I arrived on site to address the wiring repair on the HeatPump system. HeatPump System Repair: Addressed the wiring issue on the HeatPump. Corrected the wiring. Reprogrammed the thermostat. Left the system operating. Upon arriving at the property, I mentioned to the client about this day's visit. We proceeded to verify the heat pump system. We re-wired the Heat pump system. We reprogram the Thermostat for heat pump. We run and monitor the system in both AC & heat pump mode. The system responded correctly. No failures occurred after completing the repairs. I explained the situation to the client, the client understood and thanked the work of this visit. The client was left with the system operating correctly at this time. -/-/-/-/-/-/-/-/- - Richard checked the customer's heat pump system and found it operating correctly after reprogramming the thermostat and ensuring all wires were connected properly. - Richard suggested replacing the thermostat batteries as a precaution to pre


Richard  .

Richard . Job Checkin

Today I arrived on site Thermostat Issue:Addressed a report that the thermostat wasn’t displaying heat mode. Identified that the thermostat wasn’t turning on the HeatPump system. Next Steps:Will verify the system wiring. Upon arriving at the property, the client explained to me that the tstat is not displaying heat mode. I checked the tstat settings. I found the tstat set up for AC only. Set up thermostat as a heat pump systems. I found that the system is only operating in AC mode. The O/B of the condenser unit is not energized to start in Heat mode. They previously the last tech(Nigel) replaced a switching relay in the AHU and programmed the tstat AC only. The client had to leave the property and asked me to notify the office to schedule an appointment to return to verify the system to solve the failure. The client mentioned that it would be good for her to schedule the appointment on Wednesday the 15th or Thursday the 16th. Office to contact the client to schedule and conf


Antonio S.

Antonio S. Job Checkin

Furnace maintenance

Furnace maintenance

Mark E.

Mark E. Job Checkin

Heating tune ups

Heating tune ups

Lorenzo M.

Lorenzo M. Job Checkin

Maintenance on Weil-McLain boiler

Maintenance on Weil-McLain boiler