Will was excellent - punctual, gracious, professional, efficient and explained his findings thoroughly.
Not an easy job - lots of stairs, narrow stairways. They all took great care not to damage anything, moved big pieces of furniture around and back again. Clear explanations of new thermostats.
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-D510-71929C5DDFB14BCFA48EA420F094C9B4 check water leak coming from the domestic hot water indirect tank hot water outlet highly recommend to replace the tank due to the leak and the internal components being compromised also the expansion tank is defective and needs to be replaced please see photos discussed the issue with homeowner and he understands the situation office personnel please follow up with the homeowner
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-853F-749592B1410E474282B9A734E3B07811 Customer has a musty smell from the first floor AC unit- He states when he turns the system on the first floor has a bad odor: At arrival note order in home Called for cooling on the thermostat- There is a slight smell, but nothing overpowering Check the furnace coil condenser system in the Mechanical room off of the garage Found it completely plugged filter- Replaced provided by customer Also replaced the second floor filter in the return grill provided by the customer Indoor blower motor wheel and assembly- dirty Check the return ductwork- dirty Check the supply ductwork on the system- dirty Check for a mold or bacterial growth- none found Explain all findings with homeowner as he was with me throughout the service call Customer also stated that they have not done an annual maintenance in the past 10 years Recommended Maintenance on furnace coil condenser system syst
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-D939-6204A80558214FB59176F760E7BB1442 Customer has a lack of hot water from his NTI boiler with indirect storage tank: At arrival system is off on lockout error 6 Inspected the flame rod and the hot surface igniter inside of the boiler- showing heavy ware Clean the flame rod with copper bristle brush, and polished clean with steel wool Reinstall both components and secured in place Reset boiler and test system operations: Igniter is glowing up. The boiler is not firing. System is going into a lockout error six again Spoke with NTI Technical support- Check voltage going to gas valve- 24 DC volts at molex plug- okay Tech-support stated that these plugs were out overtime and lose connection to the gas valve stems Resecured Molex connector to gas valve and secured with screw Return power to boiler and test operation- Boiler fires normally And is on and running Cycle boiler on and off (3) With customer- Boiler is
(1) TCC AC Maintenance - TRANE - 410A - tested high and low voltage components ok, inspected air filter dirty supplied and replaced 14x30x1 air filter, checked evaporator coil and cleaned, chemically cleaned coils and tested primary drain pan, while testing primary drain pan noticed that sewer system has a slow blockage that will only get worse. Noticed small amounts of water back flowing into unit. Spoke to client about reviving plumbing service will have the office contact client to schedule to unclog drain. Checked delta T ok receiving good temperature split, checked safeties ok, noticed indoor unit zoning panel has signs of corrosion, board currently operational, checked condenser pressures noticed Evap below freezing, checked capacitor ok checked contactor ok electrical components within range, sprayed and washed down condenser coils, Unit is currently operational and cooling at this time, Follow Up Action: Office to contact client to schedule Plumbing service for restricted pipin
New Trane Air Handler with Hot water coil install
Maintenance on ADP central A/C system
Install high efficiency Burnham boiler.
High efficiency water boiler with two zones of Unico high velocity mini ducts and Trane Heat Pumps. HVAC renovation.