View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-F328C5C619A743FE99F4C057FF5DD237 Return to replace expansion tank and relief of gas fire water boiler: At arrival, the boiler is on and running shut System down at service switch the current boiler pressure is just under 30psi and the relief valve is not dripping Isolated expansion tank at ball valve removed additional pressure from tank and removed the expansion tank from boiler piping the tank is completely filled with water - drain out bad tank and removed the from home installed and secured brand new expansion tank in boiler piping open ball valve to new expansion tank letting tank fill and monitoring boiler pressure- okay boiler pressure is back down at a normal 20psi return power to boiler and test system operations multiple radiant, radiator and hydro zones are calling and boiler fires- normal operations monitor boiler pressure and temperature- okay boiler then gets demand call for DHW- test and
Gas Hot Water Boiler. Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, brush and vacuumed-ok Check and clean thermocouple and pilot Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check GVD-Damper-N/A Check water feeder-ok Check back flow prevent-ok Check expansion tank-ok Check relive valve-ok Check Gas valve & Gas Line-ok Check Combustion Air, Flue pipe-ok Check Temperatures & Water pressure settings; Performance-ok Check and run Thermostats-okay Check circulation pump-okay Check zone valve operation-okay Water condition- ok Ran water heater, operating well at this moment. Run system, check radiators, all of them getting hot, left system operating well at this moment. No issues at this moment.. -/-/-/-/- - Richard Dominguez conducted an annual maintenance visit for the customer's boiler system. - The customer mentioned previous interactions with
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-7C6F-33333D8316254752B0AF1CF18699BFB5 Customer is having an issue with the basement radiant heat zone as well as water leaking from the boiler: The customer brought me to the basement radiant heat thermostat at arrival to show me where he was having the problem He then brought me to the boiler room where water was on the floor I identified a leak at the system relief valve After testing, I found that with a call for heat or domestic hot water that the boiler pressure is rising above 30 psi and popping relief valve The expansion tank was found, filled with water and needs to be replaced as well as the relief valve on the system The basement radiant heat system was tested At first, the thermostat was set for Celsius Switch setting to Fahrenheit Test system operations- Call for heating from radiant floor thermostat- Zone valve opens and circulator pump is on and running Cycle uponor Thermostat on and off multipl
Today I arrived on site to address the gas valve issue. Service Actions: Replaced the gas valve on the heating system steam boiler. Ran and tested the system after the gas valve replacement. Current Status: System is operating correctly at this moment. Upon arriving at the property, the client gave me access to where the boiler unit is. I proceeded to verify the unit. Previously one of our diagnostic tech is defective gas valve. I proceeded to disassemble the defective gas valve. I proceeded to install the new gas valve. I proceeded to make the necessary connections and adjustments to conclude the repair. I tore the system. I did the gas leak test. No gas leaks present. I took the CO2 test. No CO2 present on this occasion. I concluded with the repair of the system. I showed the client the result of the installation of the new gas valve. The client thanked and was satisfied with the repair. This client was left with the system operating correctly at this time. View visua
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-767EAEF2FBD64986BE5A8E87186C665D Checked Dunkirk steam boiler diagnosed the gas valve is compromised and highly recommend to replace the gas valve for safety and reliability concerns also recommend to perform a maintenance on the system and replace the igniter/flame sensor please see photos for more details Maintenance agreement for Dunkirk steam boiler
Upon arrival spoke with customer. Customer is explaining he’s hearing noise from air handler. Inspect air handler in the attic. Found that system is leaking air @ the seems @ hydro coil. 16 yr old Hydro unit it poor condition. Customer is speaking with Bryan about system replacement. Conducted recommissioning on interior of air handler. Seal all seams with aluminum tape to prevent air leakage. Clean return grill and replaced restricted filter. No more air leakage. Noise @ system is now when fan is running which is normal. System is back to normal operation. Recommending to customer to have duct cleaning and sanitizing done. Customer may follow up with the office when he’s ready to move forward. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-79D303546B4342528B1360378BE6AA24
Completed heating maintenance on one steam boiler, removed and cleaned burners and igniter removed and clean pressure control and Brass fitting flushed, lower, cut off and tested turn system on checked operations, checked natural gas lines and check for carbon monoxide. None detected left system working
checked AO Smith, domestic hot water heater diagnosed water heater is leaking internally water heater Cannot be repaired and will have to be replaced. Please see photos and videos of water heater valves and access from street to existing water heater due to schools being in close proximity homeowner said Install technicians can park in her driveway to get equipment in location, shut water supply valves and discharge valve and also shut gas supply to water heater homeowner said that she has been having issues with her electricity and I recommend to her that we do electrical also can a office personnel please follow up with the homeowner
per maintenance on one steam boiler checked burners and standing pilot the system is unsafe to operate due to safety concerns as the relief valve is compromised and also the sight glass and it is not possible to remove the pressuretroll left system off as for safety concerns and issues Will have to replace the sight glass and repipe the pressuretroll (extended)reseal the chimney where the flue pipe goes in and replace the relief valve discussed the is plus the age of the system with homeowner and recommend a replacement of the boiler View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-86614DA913514B62A9FF40F7B5125929
Upon arrival spoke with customer. Customer is explaining that he had a few people working on the boiler where parts were replaced. Customer was told parts that were replaced I.e Honeywell zone valve and relay should solve his problems. Customer is still having intermittent issues with the boiler where it will randomly fail to operate. Customer will reset boiler and system will begin to work once more. Customer reset boiler prior to arrival where system is operational, unable to diagnose a working system. Informed customer that based on the current condition of the boiler we could start a maintenance/recommissioning process to improve the condition of the boiler. At that time we can do a full assessment of boiler. Office to follow up with customer to schedule return visit for maintenance. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-92E097A7F4054D0BBC5062832D0A7DA7
Duct cleaning and sanitizing Performed duct cleaning and sanitizing on 1st floor basement system. Remove and vacuum clean all ceiling registers in basement. Clean floor grilles to remove dust & debris before cleaning w/ duct cleaning machine. Disconnect all flexible duct Clean and polish all grilles. Clean return ductwork, cut access opening to thoroughly clean ducts. Secure with patch plate and sliver tape. Ran system and sanitize. All good View visual findings from this job here - https://visionshare.xoi.io/?id=XA-AC4C-3D0134CFFB5C4880AB9401FD0D22F7F5
Performed heating maintenance on two Goodman gas fired furnace checked electrical and mechanical components and cleaned burners and igniters and flame sensors replaced filter in the attic the basement filter will be replaced after the duct cleaning is completed by Lorenzo/will turned systems on and checked operations and performed carbon monoxide test left system working and turned off at the thermostat
Performed heating maintenance on one Ameristar gas fired furnace
Today I arrived on site: AC System - Starter Cap Replacement:Identified malfunctioning starter cap on the 1st floor foyer AC system. Replaced the 45/10 uf starter cap. Upon arrival at the property. I explained to the client the reason for the visit. The client was waiting for us to make the relationship. I proceeded to verify the condenser unit of the 1sr floor foyer. I proceeded to disassemble the starter cap malfunctioning. I proceeded to install the new starter cap. I concluded with the installation of the new starter cap. I started system and monitoring for a few minutes. I checked the system pressures. Stable pressures on this occasion. 125psi suction pressure. The client was left with the system operating correctly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-FA0C8BBF77E341EBBF724AE107EE779C
Today I arrived on site to address the issue with the thermostat. Thermostat Issue:Found the thermostat locked in heat mode. Unlocked the thermostat. System Check:Confirmed the heating and AC systems (rooftop units) are now responding correctly to the thermostat. Upon arrival at the property. The client explained to me that someone locked the tstat in heat mode. The customer said that he turned off the power of the unit to prevent the system from continuing to run in heat mode. The client directed me to where the tstat is. I proceeded to verify the tstat. I found the tstat locked and calling poo Heat. I proceeded to unlock the tstat. Successfully unlocked the tstat. I put the tstat in off position. I proceeded to check the rooftop unit on the 2nd floor. I put the power back in on position. Start the tstat from the tstat. The system started normally. The customer mentioned that he just changed the batteries of the tstat. The batteries are new. I monitor the system for a