11 Kimball Place
Mount Vernon, NY 10550
914-793-7700

Job Locations
for larchmont, ny


Map of Larchmont NY
Mark E.

Mark E.


Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A3D0-6F2FC81A7CE5487F9E6CA5A15D75107B Customer has water leaking from the master bedroom, Trane Mitsubishi ductless air handler: At arrival the AC is on and running Water is leaking from the indoor head onto the floor beneath instead of the condensate pump underneath the system Shut power to the system off Open the indoor air handler cabinet- Filters are very dirty- Customer washed them clean while on site The primary pain is filled with water and not draining into the condensate pump below Remove the reservoir of the condensate pump and connected shop vac- Vacuumed out the drain line off of the ductless system and all water from the primary pan to clear the blockage Then simultaneously flushed freshwater into the primary pan while shop vacuuming out flushing the systems drain line Reconnected reservoir to condensate pump Tested system drainage operations: Pour water over the evaporator coil into the primary