View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-CD0FE02A5CD54DCE94EFC94938557BCE Preform maintenance on (1) gas steam boiler with baseboard heating zone: * shut down thermostats and shut power down to the boiler * removed the boiler cover door * boiler and all components covered in dust and debris * inspected the pilot flame- very weak and worn down thermocouple- spoke with the customer and she approved the replacement of this component * Shut down the pilot at the gas valve * Disconnected and removed all burner tubes and pilot assembly from burner section of boiler * Vacuum and dusted out burner section of boiler under heat exchanger * Vacuum and brushed out all, burner tubes, clean and clear * Vacuum and dusted boiler cabinet, Piping and components, clean and clear * Perform full maintenance on pilot assembly, and gas orifice * Installed brand, new thermocouple, and pilot assembly and secure to gas valve * Reinstalled all burner tubes and relight