View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-B4EC246826864EADB74AC9D54E9226D2 Preform maintenance on one gas, fire, furnace with bypass humidifier and UV light kit + dryer vent cleaning: At arrival the customer stated that they just got a new dryer unit and does not want to move forward with the vent cleaning today. Confirmed he did not want this service. Shut power down to furnace * open furnace and blower cabinet door * Removed flame sensor and hot surface igniter * Clean flame sensor with copper bristle brush and polished with steel wool * Inspected hot surface igniter- okay * Removed fresh air intake from top of furnace- lots of leaves and debris - vacuumed clean * Vacuum and dusted out furnace cabinet and components, clean and clear * Vacuum and brushed burner jets clean and clear * Vacuum and dusted blower cabinet and components, clean and clear * Secured I inspected all electrical wiring, Connections and components * Chemically sprayed and