View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-C423D1A2B819422DA12AECC7392951DD Perform maintenance on Goodman gas fired furnace with two zones: * power down equipment * Open furnace and blower cabinet doors * Both compartments and components are filled with debris and dust * Disassemble burner section of furnace, removing flame sensor, Hot surface igniter and burner tray * Vacuum and dusted out furnace cabinet and components, clean and clear * Vacuum and brushed out burner jets, clean and clear * Vacuum and dusted out debris from blower cabinet and components * Vacuum and dusted out filter rack on system * Vacuum and dusted furnace cabinet / Duct work and components, clean and clear * Clean the flame sensor with copper bristle brush and polished with steel wool * Inspected hot surface igniter: Showing heavy wear and replacement as recommended * Replaced and dated customer provided Aprilaire 413 air filter * Secured and inspected electrical wiring a