Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-15F7-82B22CF568BB46B090C1AA8E46086571 Preform maintenance on (1) gas fired water boiler with (2) unico high velocity hydro air handlers: GAS WATER BOILER: * shut power to boiler * removed boiler cover door, flame guard and roll out switch and all burner tubes * vacuumed and dusted out boiler cabinet and components clean and clear * vacuumed and dusted out burner section under heat exchanger * vacuumed and dusted piping and components * brushed out and vacuumed / polished all burner tubes clean and clear * cleaned spark igniter with brass bristle brush and polished with steel wool * inspected heat exchanger / glue piping and damper / motor- okay * test and check expansion tank, water feed / back flow, air vents and system relief valve * secured and inspected all electrical wiring and connections * reassemble boiler and return power to system * both zones are calling for heating- boiler fires * Monitor syste