View visual findings from this job here - https://visionshare.xoi.io/?id=XA-57DC-25A8608146B84EA8AE0EFE481A402EAD Perform heating and cooling maintenance on Lennox furnace coil condenser system that serves the entire home: The system has not been maintained in a number of years Shut Power off the system at arrival * removed customers air filter * removed flame sensor : Cleaned with copper bristle brush, and polished with steel wool * removed hot surface igniter: Inspected igniter showing heavy signs of wire and replacement is recommended * Vacuum and dusted out furnace cabinet and components * Vacuum and dusted out blower cabinet and components * Dusted and vacuumed electrical wiring and components, securing all connections, and polishing clean * inspected inducer motor and flu piping- okay * Inspected blower wheel- slight build up * Replaced air filter provided by customer * 23.5 x 23.5 x 1 * There is little access to the evaporator coil as it is encased in custom ductwork cabinet