Perform maintenance on one gas fired water boiler, and one heat pump : ( luxaire heat pump ) Heat pump: Open air handler cabinet Chemically sprayed, brushed and rinsed, indoor evaporator coil, clean, and clear Chemically treated primary pain and added condensate tablets flushed and tested all drainage with freshwater to confirm normal operations and no leaks replaced air filter provided by customer Inspected indoor blower motor wheel and assembly Tested nest thermostat on first floor of home and call for heating- Both air handler and condensing unit are on and running Check and monitor refrigerant pressures and temperatures are condensing unit- ok Cleaned and dusted out electrical cabinet and components Chemically sprayed washed and rinsed outdoor condenser coil cabinet and fan blades, clean and clear Heat pump system is fully maintained an operational Gas water boiler: At arrival The boiler is off. The customer stated that the boiler turns on and runs, even though there is no