(1) AC Maintenance - BRYANT - R22 - Upon arrival had to wait until 8am to start due to no workmen in residence before 8. Tested high and low voltage components ok, checked indoor unit squirrel cage fan dusty recommended returning to clean, inspected evaporator coil and cleaned with chemical cleaner, tested primary drain pan ok at this time, tested condensation pump fully operational, noticed that suction line is not insulated and has been dripping on exterior of furnace for some-time, checked control board ok at this time, checked indoor capacitor within range, checked delta T ok receiving good temperature split, checked condenser pressures ok, checked electrical components at outdoor unit ok at this time, cleaned interior of condenser electricals, brushed and chemically washed condenser coils with clients hose, cleaned exterior of unit, reviewed all work completed with client, collected payment, emailed invoice. Unit is currently operational and cooling at this time.