Cooling preventative maintenance performed basement 1 Check filter - 20x25x4 new today Check coil for any buildup or debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 35+5 @ 35.08+5.01 Check OD fan Amp - 1.12 Check compressor Amp - 10.25 Verify pressures and HP-SC/LP-SH Delta T - 19° The Air handler and AC are in optimal running conditions. Cooling preventative maintenance performed basement 2 Check filter - EAC cleaned today Check coil for any buildup or debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD -45+5 @ 44.5+4.94 Check OD fan Amp - 1.28 Check compressor Amp - 9.43 Verify pressures and HP-SC/LP-SH Delta T - 18° The Air handler and AC are in optimal running conditions. Cooling preventative maintenance performed attic 3 Check filter - 20x25x4 new today Check coil for any buildup or debris in drain pan and flush with water Set up t