Gas heating preventative maintenance performed east Check filter - 210 new today Clean flame sensor Ohm test igniter: 68ohms Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.4 Check amp draw on inducer motor:1.0 Check delta T - 45° Furnace is in optimal running conditions Gas heating preventative maintenance performed west Check filter - 210 new today Clean flame sensor Ohm test igniter: 70ohms Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.8 Check amp draw on inducer motor:0.9 Check delta T - 55° Furnace is in optimal running conditions Electric Heating preventative maintenance performed Turn heat on at thermostat Blower motor ECM - no concerns Temp rise at 49° for emergency heat Furnace and heat pump in optimal running conditions