Seth cell 614-394-3279 Three system heating equipment multi-stage geothermal package, geothermal split, dual fuel split. 2 x attic air handlers, one basement Waterfurnace Envision package system All geothermal split and package systems are running in good condition requiring little maintenance after the move-in inspections and major overhaul cleanings performed a few months ago. Both geothermal air filters are in like new very good condition with no service required Test run multi-stage heat pump and all auxiliary electric resistance heat Both geothermals are in very good condition Over the garage system is 33 years old this season original to the house in 1992. The single stage Lennox r22 heat pump turned on and produced good warm air in heat pump mode but failed to initiate the gas furnace in auxiliary emergency heat mode on the Vivint control system electrical diagnostics determined that the thermostat is not producing a W signal with a call for auxiliary emergency heat. Dur