403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for columbia, md


Map of Columbia MD
Alex W.

Alex W.


Job Checkin

February 16th 2023 I installed 2 led wafer 6 inch multi color recess lights in the upstairs office I ran a 14-3 wire from the existing switch in the front left bedroom to the middle of the ceiling where i installed a fan brace box to install next visit for a customer supplied ceiling fan. I installed a new fan wall switch control I removed all double tapped neutrals and grounds in the main electrical panel then I separated then to meet current national electrical code requirements. I also removed 2 single pole breakers on a multi feed and installed a 2 pole 15 amp square d electrical breaker We will return February 24th to complete the rest of the work Customer is also a VIP member #review I installed four LED wafer recessed lights in kitchen are used existing switch leg after removing surface mounted light fixture Then in the dining room I installed two LED wafer recessed lights and ran a switch leg to an existing three gang switch box I then installed Caseta smart switches