Alex W.

Alex W. Job Checkin

Customer called about gfcis going out and fan not working I removed the transmitter inside of the fan canopy then I wired the fan wires to the 14-3 inside the box. After That I installed a fan switch that controls the light fixture and the fan speed. I removed a chandelier and installed a new customer supplied chandelier I removed all the outlets that were on the load side of the basement gfci. I installed a 15 amp arc fault breaker. Then I removed a box in the basement and put it on the other side of the wall which will be under the steps because the customer is having the basement finished and drywall. I then installed Gfcis in each location line siding every gfci wire so they are covered by current code but also if a gfci trips it will not affect any other location just the one that tripped


Krysta T.

Krysta T. Job Checkin

Installed 4 new LED recessed wafer lights in work out room tapped off existing switch. Room had open attic above to fish wires around. Installed new customer supplied ceiling fan in 2nd bedroom on the left at the top of the stairs. Tapped off smoke detector circuit. I installed ceiling fan in 1st bedroom on 2nd floor last visit. Haas and Sons is not responsible for drywall repair