Job Checkin

Customer called about gfcis going out and fan not working I removed the transmitter inside of the fan canopy then I wired the fan wires to the 14-3 inside the box. After That I installed a fan switch that controls the light fixture and the fan speed. I removed a chandelier and installed a new customer supplied chandelier I removed all the outlets that were on the load side of the basement gfci. I installed a 15 amp arc fault breaker. Then I removed a box in the basement and put it on the other side of the wall which will be under the steps because the customer is having the basement finished and drywall. I then installed Gfcis in each location line siding every gfci wire so they are covered by current code but also if a gfci trips it will not affect any other location just the one that tripped