This solution includes installing a 100 amp sub panel next to the main panel in the basement due to the fact that there are tandem breakers in the main panel also incorrect wiring two breakers multi feeds that are going to 15 amp and then 20 amp single pole breakers so we will separate those wires and move wires to the subpanel allowing more spaces in the main electrical panel also it will fix all the safety issues allowing the main panel to last longer And safer We will run wires from an existing receptacle in the basement then run or wires throughout the basement and install three GFCI’s in the basement where the customer wants them these circuits must be GFCI protected due to the fact that it’s an unfinished basement with a concrete exposed floor Previous electrician put a plastic box on a concrete wall and installed a regular receptacle in the basement I will remove the plastic box and the receptacle and put a metal 1900 box with a GFCI receptacle and RS cover plate for deep fre