824 S Central Expressway, Suite 100
Anna, TX 75409
903-482-4900

Job Locations
for anna, tx


Map of Anna TX
braydenwebb@hotmail.com

braydenwebb@hotmail.com


Job Checkin

1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange 16. Inspected surge protector to ensure it has not taken a power surge. All was well with normal unit operation. Customer advised he took care of dryer vent problem from last visit. Advised customer that filter rating Merv.16 will produce additional stress on the system and recommended merv 13. Unit in operation upon departu