I performed a single system cooling maintenance on a 2020 gas carrier system. I checked amps, capacitor, filter, electrical, drains, and cleanliness. The system could use some duct cleaning and blower cleaning. Dust build up can cause the compressor to fail, evaporator coil to leak, and the blower motor to go out. The system currently only has an emergency pan float switch and with the current drain configuration is basically useless. I propose that a in line float and a blow out valve. These items will allow the detection of clogging to be faster and allow the homeowner to clear it. The capacitor was beginning to read weak and I offered a replacement under warranty and a turbo200. The customer approve the turbo200. I installed it and tested the unit for proper operation. 5 year warranty TURBO200 MULTI USE CAPACITOR 2.5-67.5 MFD 370 - 440V SIMILAR TO A BATTERY, CAPACITORS HELP START MOTORS BY STORING CURRENT. A DAMAGED CAPACITOR CAN DAMAGE THE MOTOR IF NOT SERVICED. REGULAR MAIN