Sprayed adhesive spray to interior insulation on the top side of blower motor housing. Taped and seal existing Armaflex insulation on suction line copper where it was entirely exposed within the attic up to where it meets the wall on both units. I possibly believe that it is possibly split open entirely where it goes through the wall. On this return trip, found water in the pan on both unit due to the condensation dripping from the exposed suction line. Asked homeowner when last time filter was installed and was unaware. Due to no filter in systems there could be large buildup of debris on evaporator coil…can verify if management company/homeowner authorizes, complete diagnostics. Both units require: 20x20x4 air filters (customer requested) these filters not on service truck Water removal from emergency drain pans Up to 6”PVC extension at primary tee and pvc caps or level 3 bundle Insulation on primary drains up to 6’ Condenser coil wash Full AC check on entire system….refrigeran