We arrived at our clients home for a two system cooling maintenance inspection. We began by first the bathroom exhaust vent that had a bird nest inside of it. This vent is on the right side of the home and we found three small baby birds. The vent hose is compromised as well as the exterior cap. We advised our client to reach out to pest control to have them remove the birds properly. We then proceeded to perform the maintenance on both outdoor heat pump units. Everything electronically tested within range. Except for the start amps on both compressors for both units. Both of them are reaching manufacturers limits. We discussed adding compressor savers to both outdoor units to help preserve and protect the compressors from over amping and failing completely. We also washed both outdoor coils as part of today’s maintenance. We then proceeded inside, the client did provide air filters to be replaced for both attic units. We did run our air advice today and will be sending the report to